6. Use a Phillips screwdriver to loosen the four screws of the terminal block box cover and
then remove the cover (fig. 2).
7. Loosen the two screws of the mains cable's safety gate and then remove the safety gate
(fig. 2).
8. Guide the mains cable through the round opening in the terminal block box and connect the
mains cable with the terminal block inside the terminal block box:
Brown cable = L
Blue cable = N
Green/yellow cable = PE/ground wire, grounding symbol
The ground wire must be connected to the terminal block under all
circumstances.
If the product is serving as a replacement for an existing light and there is
no ground wire, do not install the product. First install the appropriate supply
leads.
If no ground wire is connected, there will be voltage applied to the metal
product housing in the event of an error. This poses a risk of fatal injury due
to electric shock!
Make sure that the cables are not bare for too long as this may cause short-
circuiting.
Make sure that all screw connections on both sides of the terminal block
are tight.
9. Reinstall the safety gate and then attach it using the two screws.
10. Close the terminal block box and make sure the rubber sealing is positioned properly.
11. Put the terminal block bracket and the excess length of the mains cable into the lamp
housing.
Make sure that the cables are not squeezed, bent or damaged in any other
way. Do not exert any force when installing the product.
12. Attach the lamp housing to the floor mount bracket using the four short screws.
13. Turn on power to the circuit and check to see if the product works.
If the LEDs do not light up, turn off power to the circuit immediately (turn off
circuit breaker and/or automatic fuse).
Then check the connection to the power circuit.
In case of doubt, contact a professional (i.e. an electrician).

Maintenance and cleaning

Never use aggressive cleaning agents or chemical solutions, as such would
damage the housing (discolorations).
Never point a water jet, for example such of high-pressure cleaning
equipment, at the lamp, as that could damage the seals!
• Besides occasional cleaning, the device is maintenance-free.
• Turn off the product and let it cool down sufficiently before cleaning.
• Wipe the outer surface with a clean, soft cloth only. In order to remove stubborn staining, you
may slightly dampen the cloth with warm water.
Disposal
Electronic devices are recyclable waste and must not be disposed of in the household
waste.
At the end of its service life, dispose of the product according to the relevant statutory
regulations.
You thus fulfil your statutory obligations and contribute to the protection of the environment.
fig. 2

Technical data

a) General
Operating voltage .......................... 220 – 240 V/AC, 50 Hz
Power consumption . ...................... 8 W
Illuminant ....................................... 12 x Seoul LED, not dimmable
Colour temperature . ....................... 3000 K
Luminous colour ............................ warm-white
Luminous flux ................................ 404 lm
Protection class ............................. I
Protection type . .............................. IP54
Operating temperature .................. -30 to +45 ºC
Storage temperature . ..................... -30 to +55 ºC
Humidity . ........................................ 0 – 90 %
Dimensions (W x H x D) ................ 75 x 850 x 215 mm
Weight ........................................... approx. 1060 g
b) LED driver (built-in)
Input voltage . ................................. 220 – 240 V/AC, 50 Hz
Input current .................................. 40 mA
Output voltage ............................... 22 V/DC
Output current . ............................... 350 mA
These operating instructions are published by Conrad Electronic SE, Klaus-Conrad-Str. 1,
D-92240 Hirschau (www.conrad.com).
All rights including translation reserved. Reproduction by any method, e.g. photocopy, microfilming,
or the capture in electronic data processing systems require the prior written approval by the editor.
Reprinting, also in part, is prohibited.
These operating instructions represent the technical status at the time of printing. Changes in
technology and equipment reserved.
© Copyright 2013 by Conrad Electronic SE.
V1_0813_02-ETS-Mkde

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis