SAFETY INSTRUCTIONS
When moving or relocating the air conditioner, consult experienced service technicians
for disconnection and reinstallation of the unit.
The appliance shall not be installed in the laundry.

ELECTRICAL WARNINGS

The power supply must be of rated voltage with special circuitry for the appliance.
The diameter of the power cord must comply with requirements.
A multi-pole switch shall be installed in the fixed wiring in accordance with the wiring
rules and the appliance must be earthed in conformity with national electrical safety
standards.
An all-pole disconnection switch having a contact separation of at least 3 mm in all poles
should be connected in fixed wiring.
Do not use extension leads, multiple sockets or adapters. The electrical components
must not be accessible to the user after installation. Do not use the appliance when you are
wet or barefoot. Do not operate this appliance if it has a damaged power cable or plug, if it
is not working properly, or if it has been damaged or dropped.
If the supply cord is damaged, it must be replaced with an identical one by the
manufacturer, its service agent or similarly qualified persons in order to avoid a hazard - risk
of electrical shock.
A residual current device (RCD) having rated residual operation current not exceeding
30 mA shall be incorporated in fixed wiring according to national law.
The temperature of refrigerant circuit will be high, please keep the interconnection cable
away from the copper tube.
Ensure safe grounding and a grounding wire connected with the special grounding
system of the building, installed by professionals. The appliance must be fitted with
electrical leakage protection switch and an auxiliary circuit breaker with sufficient capacity.
The circuit breaker must also have a magnetic and a thermal tripping function to ensure
protection in case of short-circuit and overload.
Model
Required capacity of circuit breaker
For the connection of power cord and cable connection between indoor and outdoor
units, please see the wiring diagram on the appliance.

CLEANING AND MAINTENANCE

WARNING: Ensure that the appliance is switched off and disconnected from the
power supply before performing any maintenance operation; never use steam cleaning
equipment - risk of electric shock.
Maintenance and repair requiring the assistance of other skilled personnel shall be
carried out under the supervision of the person competent in the use of flammable
refrigerants.
Servicing shall only be performed with equipment as recommended by the
manufacturer.

DISPOSAL OF PACKAGING MATERIALS

The packaging material is 100% recyclable and is marked with the recycle symbol (
packaging must therefore be disposed of responsibly and in full compliance with local authority regulations
governing waste disposal.
9K & 12K
16A
- 21 -
18K
20A
). The various parts of the
24K
25A