14. Troubleshooting

Fault
Possible cause
Motor does not work
Motor, cable or plug defective, fuses burnt
The motor starts up slowly
Voltage too low, coils damaged, capacitor burnt Contact the utility provider to check the voltage.
and does not reach oper-
ating speed.
Motor makes excessive
Coils damaged, motor defective
noise
The motor does not reach
Circuits in the network are overloaded (lamps,
its full power.
other motors, etc.)
Motor overheats easily.
Overloading of the motor, insufficient cooling of
the motor
Saw cut is rough or wavy Saw blade dull, tooth shape not appropriate for
the material thickness
Workpiece pulls away
Excessive cutting pressure and/or saw blade not
and/or splinters
suitable for use

Service information

Please note that the following parts of this product are subject to normal or natural wear and that the following parts are therefore also
required for use as consumables.
Wear parts*: carbon brushes, saw blade, table inserts, dust collecting bags
* Not necessarily included in the scope of delivery!
Remedy
Arrange for inspection of the machine by a specialist.
Never repair the motor yourself. Danger!
Check fuses and replace as necessary
Arrange for inspection of the motor by a specialist. Ar-
range for replacement of the capacitor by a specialist
Arrange for inspection of the motor by a specialist
Do not use any other equipment or motors on the same
circuit
Avoid overloading the motor while cutting, remove dust
from the motor in order to ensure optimal cooling of the
motor
Resharpen saw blade and/or use suitable saw blade
Insert suitable saw blade