6.5
DIP switch settings (Part No. 72585B)
Fig. 9: Electronic module
DIP switch = OFF (factory setting)
All internal LEDs on
No function
Quiescent current operation
Potential-free contact (continuous signal)
6.5.1 Jumper position
3
2
Fig. 10: Location of the jumper on the back side of the electronic module
The DIP switches are set at the factory for standard operation of the compact call set (all switches in
OFF position).
Changing the settings is only required in special cases.
For detailed connection diagrams for the components, see section 5.
76910XE / 02.2018
Location of the DIP switch (front side)
DIP switch = ON
Jumper position
Make contact
3 2 1
potential-free (NO)
Break contact
3 2 1
potential-free (NC)
Compact Call Set
TOP
1
All internal LEDs off
No function
Operating current operation
Potential-free contact (cycling signal)
Connection example for the
contact
C
NO
C
NC
Max. contact load 24 V DC / 1 A
23