Herunterladen Inhalt Inhalt Diese Seite drucken

Setting Up; Mains Connection; Operation - Parkside PHD 150 D3 Betriebsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

flow preventer in conformity with EN
12729 type BA must be used.
Water that has passed through a backflow
preventer is classified as undrinkable.
A backflow preventer is available in spe-
cialist shops.
Employ an ordinary garden hose for
the water intake and ensure sufficient
length.
Use the device on a domestic water
connection with an output of at least
450 l/h.
Irrespective of the water pipe, you can
also use the device (for example, rain
barrel) through the integrated water
suction function. This function must only
be used with a suction hose with a fil-
ter basket.
The device itself must not be immer-
sed in open water sources. There
is a risk of personal injury from an
electric shock.
Do not draw in any water from na-
tural accumulations. There is a risk
of contamination from backwashed
cleaning agent.

Setting up

1. Fold the handle after upwards until it
engages with a resistor. Fold out the
handle of the hose reel. You audibly
snaps.
2. Slide the holder for mains cable (11)
and the jet gun holder (4) onto the
guides on the device housing.
3. Connect the high-pressure fitting (jet
gun) (2) to the jet gun (1). Use the fork
spanner from the package.
4. Connect the feed hose to the water
supply and allow water to escape from
the other end of the feed hose with no
bubbles, in order to expel the air from
the feed hose. Switch off the water tap.
5. Connect the feed hose with the help of
the quick connector for garden hose
adapter (15) with the water connection
coupling (9) and the water connection
(10) on the device. Always use the fil-
ter insert (8) and clean this as required
(bayonet fixing).
6. Plug in and turn the turbo dirt blaster
(18) or the standard Vario nozzle (19)
or the rotating wash brush (20) to con-
nect to the jet gun (1).
7. To change the jet tube (18/19) or the
rotating wash brush (20) push in the
tube or brush and turn in the opposite
direction.

Mains connection

The pressure cleaner you have acquired
is already fitted with a mains plug. The
equipment is designed for connection to
an earthed wall socket with a residual
current operated device (RCD switch) at
230 V ~ 50 Hz.
Only operate the pressure cleaner
after all the above points have been
observed.
1. Ensure that the pressure cleaner is
turned off by its ON / OFF switch (6).
2. Insert the mains plug into the mains
socket

Operation

Be prepared for the recoil
force of the emitted wa-
ter jet! Ensure that you are
standing firmly and that you
are holding the gun (1) se-
curely, otherwise you could
injure yourself or other peo-
ple.
GB