2.8.3.21 Parameter request
When the 01V96 receives this data, it will transmit Sort Table Data.
System exclusive message
STATUS
11110000 F0
Manufacture's ID number (YAMAHA)
ID No.
01000011 43
n=0-15 (Device number=MIDI Channel)
SUB STATUS 0011nnnn 3n
MODEL ID (digital mixer)
GROUP ID
00111110 3E
01V96
MODEL ID
00001101 0D
Library sort table
ADDRESS
00010011 13
Library type
0000ffff 0f
End of exclusive
EOX
11110111 F7
2.8.3.22 Parameter change
Reception
This is received if [Parameter change RX] is ON and the [Rx CH] matches the
device number included in the SUB STATUS.
This is echoed if [Parameter change ECHO] is ON.
When this is received, the same processing that is executed when the key speci-
fied by Address is pressed (released).
Transmission
If [Parameter Change ECHO] is ON, this message is retransmitted without
change.
System exclusive message
STATUS
11110000 F0
Manufacture's ID number (YAMAHA)
ID No.
01000011 43
n=0-15 (Device number=MIDI Channel)
SUB STATUS 0001nnnn 1n
MODEL ID (digital mixer)
GROUP ID
00111110 3E
01V96
MODEL ID
00001101 0D
Key remote
ADDRESS
00100000 20
Key address H
0kkkkkkk kk
Key address M
0kkkkkkk kk
Key address L
0kkkkkkk kk
Release:0, Press:1
DATA
0ppppppp pp
End of exclusive
EOX
11110111 F7
2.8.3.23 Parameter change
When transmission is enabled by receiving a Request of Remote meter, the
specified meter information is transmitted every 50 msec for 10 seconds. When
you want to transmit meter information continuously, a Request must be trans-
mitted continuously within every 10 seconds.
Reception
This is echoed if [Parameter change ECHO] is ON.
Transmission
When transmission has been enabled by a Request, the parameter specified by
Address will be transmitted on the [Rx CH] channel at 50 msec intervals for a
duration of 10 seconds.
Transmission will be disabled if the power is turned off and on again, or if the
PORT setting is changed.
If [Parameter Change ECHO] is ON, this message is retransmitted without
change.
System exclusive message
STATUS
11110000 F0
Manufacture's ID number (YAMAHA)
ID No.
01000011 43
n=0-15 (Device number=MIDI Channel)
SUB STATUS 0001nnnn 1n
MODEL ID (digital mixer)
GROUP ID
00111110 3E
01V96
MODEL ID
00001101 0D
Remote meter
ADDRESS
00100001 21
ADDRESS UL
0mmmmmmm mm
ADDRESS LU
0mmmmmmm mm
ADDRESS LL
0mmmmmmm mm
Data1 H
DATA
0ddddddd dd
Data1 L
0ddddddd dd
:
:
End of exclusive
EOX
11110111 F7
* Meter data uses the unmodified DECAY value of the DSP. The inter-
pretation of the data will depend on the parameter.
2.8.3.24 Parameter request
Reception
This is received if [Parameter change RX] is ON and the [Rx CH] matches the
device number included in the SUB STATUS. This is echoed if [Parameter
change ECHO] is ON.
When this is received, data of the specified address is transmitted on the [Rx
(Sort Table)
CH] at intervals of 50 msec as a rule (although this may not be the case if the
port is being used by other communication), for a period of 10 seconds.
If Address UL= 0x7F is received, transmission of all meter data will be halted
immediately. (disable)
Transmission
If [Parameter Change ECHO] is ON, this message is retransmitted without
change.
STATUS
ID No.
SUB STATUS 0011nnnn 3n
GROUP ID
MODEL ID
(Key remote)
ADDRESS
EOX
2.8.3.25 Parameter change (Remote Time Counter)
When transmission is enabled by receiving a Request of Remote Time Counter,
the Time Counter data is transmitted every 50 msec for 10 seconds. When you
want to transmit Counter information continuously, a Request must be trans-
mitted within every 10 seconds.
Reception
This is echoed if [Parameter change ECHO] is ON.
Transmission
When transmission is enabled by receiving a Request, the Time Counter infor-
mation is transmitted on [RxCH] channel every 50 msec for 10 seconds.
Transmission will be disabled if the power is turned off and on again, or if the
PORT setting is changed.
If [Parameter Change ECHO] is ON, this message is retransmitted without
change.
(Remote Meter)
STATUS
ID No.
SUB STATUS 0001nnnn 1n
GROUP ID
MODEL ID
ADDRESS
DATA
EOX
2.8.3.26 Parameter request (Remote Time Counter)
Reception
This is received if [Parameter change RX] is ON and the [Rx CH] matches the
device number included in the SUB STATUS. This is echoed if [Parameter
change ECHO] is ON.
When this is received, the Time Counter information is transmitted on the [Rx
CH] channel every 50 msec for 10 seconds.
When the second byte of Address is received on 0x7F, data transmission will be
halted immediately. (disable)
Transmission
If [Parameter Change ECHO] is ON, this message is retransmitted without
change.
STATUS
ID No.
SUB STATUS 0011nnnn 3n
GROUP ID
MODEL ID
ADDRESS
(Remote Meter)
EOX
MIDI-Datenformat
System exclusive message
11110000 F0
Manufacture's ID number (YAMAHA)
01000011 43
n=0-15 (Device number=MIDI Channel)
MODEL ID (digital mixer)
00111110 3E
01V96
00001101 0D
Remote meter
00100001 21
ADDRESS UL
0mmmmmmm mm
ADDRESS LU
0mmmmmmm mm
ADDRESS LL
0mmmmmmm mm
Count H
0ccccccc ch
Count L
0ccccccc cl
End of exclusive
11110111 F7
System exclusive message
11110000 F0
Manufacture's ID number (YAMAHA)
01000011 43
n=0-15 (Device number=MIDI Channel)
MODEL ID (digital mixer)
00111110 3E
01V96
00001101 0D
Remote Time counter
00100010 22
0:Time code, 1:Measure.Beat.Clock
0000tttt 0t
Hour / Measure H
0ddddddd dd
Minute / Measure L
0ddddddd dd
Second / Beat
0ddddddd dd
Frame / Clock
0ddddddd dd
End of exclusive
11110111 F7
System exclusive message
11110000 F0
Manufacture's ID number (YAMAHA)
01000011 43
n=0-15 (Device number=MIDI Channel)
MODEL ID (digital mixer)
00111110 3E
01V96
00001101 0D
Remote Time counter
00100010 22
0:Transmission request,
0ddddddd dd
0x7F:Transmission stop request
End of exclusive
11110111 F7