Herunterladen Inhalt Inhalt Diese Seite drucken

Yamaha 01V96 V2 Bedienungsanleitung Seite 309

Inhaltsverzeichnis

Werbung

If [TABLE] is selected
Control change
STATUS
1011nnnn Bn
Control number (0-95, 102-119)
DATA
0nnnnnnn nn
Control Value (0-127)
0vvvvvvv vv
If [NRPN] is selected
Control change
STATUS
1011nnnn Bn
NRPN LSB
DATA
01100010 62
LSB of parameter number
0vvvvvvv vv
Control change *1
STATUS
1011nnnn Bn
NRPN MSB
DATA
01100011 63
MSB of parameter number
0vvvvvvv vv
Control change *1
STATUS
1011nnnn Bn
MSB of data entry
DATA
00000110 06
MSB of parameter data
0vvvvvvv vv
Control change *1
STATUS
1011nnnn Bn
LSB of data entry
DATA
00100110 26
LSB of parameter data
0vvvvvvv vv
*1) The second and subsequent STATUS need not be added during
transmission. Reception must be implemented so that reception oc-
curs whether or not STATUS is present.
2.4 PROGRAM CHANGE
Reception
If [Program Change ECHO] is ON, these messages are echoed from MIDI
OUT.
If [Program Change RX] is ON and the [Rx CH] matches, these messages will
be received. However if [OMNI] is ON, they will be received regardless of the
channel. When a message is received, a Scene Memory will be recalled according
to the settings of the [Program Change Table].
Transmission
If [Program Change TX] is ON, this message is transmitted according to the set-
tings of the [Program Change Table] on the [Tx CH] channel when a scene
memory is recalled.
If the recalled scene has been assigned to more than one program number, the
lowest-numbered program number will be transmitted. Transmission to Studio
Manager using Program Change messages will not be performed since there is
no guarantee that the contents of the tables will match. (Parameter Changes will
always be used.)
Program change
STATUS
1100nnnn Cn
Program number (0-127)
DATA
0nnnnnnn nn
2.5 TIMING CLOCK
Reception
It is used to control effects. This message is transmitted 24 times per quarter
note.
Timing clock
STATUS
11111000 F8
2.6 ACTIVE SENSING
Reception
Once this message has been received, the failure to receive any message for an
interval of 400 ms or longer will cause MIDI transmission to be initialized, such
as by clearing the Running Status.
Active sensing
STATUS
11111110 FE
2.7 SYSTEM RESET
Reception
When this message is received, MIDI communications will be cleared, e.g., by
clearing the Running Status.
System reset
STATUS
11111111 FF
2.8 SYSTEM EXCLUSIVE MESSAGE
2.8.1 MIDI MACHINE CONTROL
These messages are transmitted when the Machine Control section of the 01V96
is operated. For details, refer to the MMC specification.
2.8.2 BULK DUMP
This message sends or receives the contents of various memories stored within
the 01V96.
The basic format is as follows.
For DUMP DATA
F0 43 0n 7E cc cc <Model ID> tt mm mm [Data ...] cs F7
For DUMP REQUEST
F0 43 2n 7E <Model ID> tt mm mm F7
n
cc cc
4C 4D 20 20 38 43 39 33
tt
mm mm
cs
A unique header (Model ID) is used to determine whether the device is a 01V96.
CHECK SUM is obtained by adding the bytes that follow BYTE COUNT
(LOW) and end before CHECK SUM, taking the binary compliment of this
sum, and then setting bit 7 to 0.
CHECK SUM = (-sum)&0x7F
Reception
This message is received if [Bulk RX] is ON and the [Rx CH] matches the device
(Cn)
number included in the SUB STATUS.
When a bulk dump is received, it is immediately written into the specified
memory.
When a bulk dump request is received, a bulk dump is immediately transmit-
ted.
Transmission
This message is transmitted on the [Tx CH] by key operations in the [MI-
DI]-[BULK DUMP] screen.
A bulk dump is transmitted on the [Rx CH] in response to a bulk dump request.
The data area is handled by converting seven words of 8-bit data into eight
words of 7-bit data.
Conversion from actual data into bulk data
d[0~6]: actual data
b[0~7]: bulk data
b[0] = 0;
for( I=0; I<7; I++){
}
(F8)
Restoration from bulk data into actual data
d[0~6]: actual data
b[0~7]: bulk data
for( I=0; I<7; I++){
(FE)
}
2.8.2.1 Scene memory bulk dump format (compress)
The 01V96 can transmit and receive scene memories in compressed form.
STATUS
ID No.
SUB STATUS 0000nnnn 0n
FORMAT No. 01111110 7E
(FF)
COUNT HIGH 0ccccccc ch
COUNT LOW
(F0)
(MMC)
DATA NAME
MIDI-Datenformat
Device Number
DATA COUNT (the number of bytes that
follow this, ending before the checksum)
Model ID
DATA TYPE
DATA NUMBER
CHECK SUM
if( d[I]&0x80){
b[0] |= 1<<(6-I);
}
b[I+1] = d[I]&0x7F;
b[0] <<= 1;
d[I] = b[I+1]+(0x80&b[0]);
System exclusive message
11110000 F0
Manufacture's ID number (YAMAHA)
01000011 43
n=0-15 (Device number=MIDI Channel)
Universal bulk dump
data count = ch * 128 + cl
0ccccccc cl
'L'
01001100 4C
'M'
01001101 4D
' '
00100000 20
' '
00100000 20
'8'
00111000 38
'C'
01000011 43
'9'
00111001 39
'3'
00110011 33
'm'
01101101 6D
m=0-99, 256, 8192(Scene0-99, EDIT
0mmmmmmm mh
BUFFER, UNDO)
Receive is effective 1-99, 256, 8192
0mmmmmmm ml