Important Notice:
Gun may be cleaned with solvent or cleaning agents manually or in a conventional gun
washing machine.
The following actions damage the gun/system, may lead to the loss of the explosion-
proofness approval and entirely annull any warranty claims:
- Immersing the gun in solvent or cleaning agents, or for a period longer than required
for the cleaning process as such
- Storing the gun inside the gun washing machine
- Cleaning the gun by means of ultrasound cleaning systems
6. Possible failures in operation
Trouble
1.
Gun leaks
2.
Spray pattern is bad
3.
Paint spray flutters
4.
Material bubbles or
„boils" in paint cup
7. Spare parts (see spare part drawing at the end of this booklet)
Pos. No. Art. No. Description
1
134957
3
134767
134775
3a
134783
4
134817
9
32615
134833
32987
134791
134858
*
138909
**
142638
Cause
Foreign substances between
fluid tip and needle prevent
sealing
Soiling and wear of parts
- Too little material in cup
- Fluid nozzle not tight self-
adjusting
Leakage at the nozzle sealing
Nozzle set SATAgraph 3
Trigger
Gravity flow cup 2.5 ml with lid
Gravity flow cup 5 ml with lid
Siphon cup 5 ml with lid
Needle cap
Pack with 3 coupling nipples and sealings
End piece, cpl.
PVC hose, cpl. 3 m
Tissue hose, cpl. 2.5 m
Repair kit SATAgraph 1
O-ring kit for paint nozzle (5 pieces)
O-Ring kit for gravity flow cups (5 pcs.)
Repair
Remove and clean fluid need-
le and fluid nozzle or install
new nozzle set. Correct paint
needle adjustment.
Clean paint nozzle, paint
needle or air cap. Replace
parts.
- Refill material
- Tighten parts
- Clean sealing surface at
sealing and body
- Tighten air cap a little more
strongly
- Replace parts