All operating elements and connec-
GB
tions described can be found on the
fold-out page 3.
1 Operating Elements and
Connections
1 Input controls
2 Selector switches for microphone /
line inputs
3 Master controls with LED for the
power LED and output level indica-
tion
For mono operation, only the upper
control is required.
4 Selector switch mono / stereo
5 ON / OFF switch
6 Jack for 9 V power supply
7 Outputs (6.3 mm jacks)
L (M) for mono operation
L + R for stereo operation
8 Inputs (6.3 mm jacks)

2 Important Notes

The unit corresponds to all relevant di-
rectives of the EU and is therefore
marked with
G
The unit is suitable for indoor use
only. Protect it against dripping water
and splash water, high air humidity,
and heat (admissible ambient tem-
perature range 0 – 40 °C).
G
For cleaning only use a dry, soft
cloth, never use chemicals or water.
G
No guarantee claims for the unit and
no liability for any resulting personal
damage or material damage will be
accepted if the unit is used for other
purposes than originally intended, if it
is not correctly connected or oper-
ated, or not repaired in an expert way.
8
.
If the unit is to be put out of op-
eration definitively, take it to a
local recycling plant for a dis-
posal which is not harmful to the
environment.
3 Applications
The MMX-8 has especially been de-
signed as a pre-mixer and allows con-
nection of up to eight mono micro-
phones or four stereo microphones.
The inputs can be switched over to line
level for connection of e. g. tuner,
CD player and cassette recorder. The
mixer is ideally suited e. g. for video
dubbing or as a pre-mixer for micro-
phone groups if there are not sufficient
microphone inputs at the mixer or am-
plifier.

4 Power Supply

The power can be supplied via a 9 V
battery or a 9 V power supply unit (e. g.
PSS-906DC from MONACOR).
1) The battery (not supplied with the
unit) is inserted into the battery com-
partment at the lower side of the unit.
For this purpose unscrew the battery
compartment cover.
2) The power supply unit is connected
to the jack 9 V (6). Then an inserted
battery is switched off. A low voltage
plug 5.5 / 2.1 mm (outside / inside dia -
meter) is required. Always observe
the correct polarity: The positive pole
must be at the centre contact!
Attention!
Replace exhausted batteries in time
and remove the battery if the unit will not
be used for a longer time. Thus, dam-
age to the unit due to a leaking battery
is prevented.