Herunterladen Inhalt Inhalt Diese Seite drucken

Yamaha CL5 Referenzhandbuch Seite 290

Vorschau ausblenden Andere Handbücher für CL5:
Inhaltsverzeichnis

Werbung

2 SYSTEM REALTIME MESSAGE
2.1 SONG SELECT
Reception
Select the track number shown in the TITLE LIST screen of the USB memory
recorder.
Song select
STATUS
11110011 F3
Song number (0-127)
Song number 0sssssss ss
2.2 TIMING CLOCK
Reception
This message is used to control effects. This message is transmitted twenty-four
times per quarter note.
Echoing of this message depends on the OTHER item in the ECHO settings.
Timing clock
STATUS
11111000 F8
2.3 ACTIVE SENSING
Reception
Once this message has been received, MIDI communication will be initialized
(e.g., Running Status will be cleared) if no message is received for an interval of
400 ms.
This message is not subject to echoing.
Active sensing
STATUS
11111110 FE
2.4 SYSTEM RESET
Reception
When this message is received, MIDI communication will be initialized (e.g.,
Running Status will be cleared).
This message is not subject to echoing.
System reset
STATUS
11111111 FF
3 SYSTEM EXCLUSIVE MESSAGE
3.1 MMC
< MMC STOP >
Reception
If the [DEVICE NO.] matches or is 7F, receives this message and stops.
System exclusive message
STATUS
11110000 F0
Real time System exclusive
ID No.
01111111 7F
Destination (00-7E, 7F:all call)
Device ID
0ddddddd dd
Machine Control Command(MCC) sub-id
COMMAND
00000110 06
Stop(MCS)
00000001 01
EOX
11110111 F7
End of exclusive
< MMC PLAY >
Reception
If the [DEVICE NO.] matches or is 7F, receives this message and starts playback.
System exclusive message
STATUS
11110000 F0
Real time System exclusive
ID No.
01111111 7F
Destination (00-7E, 7F:all call)
Device ID
0ddddddd dd
Machine Control Command(MCC) sub-id
COMMAND
00000110 06
Play(MCS)
00000010 02
EOX
11110111 F7
End of exclusive
(F3)
< MMC DEFERED PLAY >
Reception
If the [DEVICE NO.] matches or is 7F, receives this message and starts playback.
System exclusive message
STATUS
11110000 F0
Real time System exclusive
ID No.
01111111 7F
Destination (00-7E, 7F:all call)
Device ID
0ddddddd dd
Machine Control Command(MCC) sub-id
COMMAND
00000110 06
(F8)
00000011 03
Deferred Play(MCS)
End of exclusive
EOX
11110111 F7
< MMC RECORD STROBE >
Reception
If the [DEVICE NO.] matches or is 7F, receives this message, and if stopped, starts
recording.
STATUS
11110000 F0
System exclusive message
(FE)
Real time System exclusive
ID No.
01111111 7F
Destination (00-7E, 7F:all call)
Device ID
0ddddddd dd
Machine Control Command(MCC) sub-id
COMMAND
00000110 06
Record strobe
00000110 06
End of exclusive
EOX
11110111 F7
< MMC PAUSE >
Reception
If the [DEVICE NO.] matches or is 7F, receives this message, and if playing, pauses.
(FF)
STATUS
11110000 F0
System exclusive message
Real time System exclusive
ID No.
01111111 7F
Destination (00-7E, 7F:all call)
Device ID
0ddddddd dd
Machine Control Command(MCC) sub-id
COMMAND
00000110 06
Pause(MCS)
00001001 09
End of exclusive
EOX
11110111 F7
3.2 BULK DUMP
This message is used to send or receive the contents of various memories stored
within the unit.
The basic format is as follows.
Command
F0 43 0n 3E cc cc 19 mm ... mm dd
dd ... ee F7
F0 43 2n 3E 19 mm ... mm dd dd F7 rx
The CL series console uses the following data types for a bulk dump.
Module Name(mm)
SCENE LIB
"SCENE___"
INPUT EQ LIB
"INEQ____"
OUTPUT EQ LIB
"OUTEQ___"
Dynamics LIB
"DYNA____"
INPUT CH LIB
"INCHNNL_"
OUTPUT CH LIB
"OUTCHNNL"
GEQ LIB
"GEQ_____"
8BandPEQ LIB
"8PEQ____"
EFFECT LIB
"EFFECT__"
Premium Effect
"PEFFECT_"
Portico5033 LIB
"P5033___"
37
Module Name(mm)
Portico5043 LIB
U76 LIB
Opt-2A LIB
EQP-1A LIB
DynamicEQ LIB
Buss Comp 369 LIB
Dante Input Patch LIB
Mixer Setup
Outport Setup
Monitor Setup
MIDI Setup
Lib Number
Program Change Table
Control Change Table
Preference (Current)
Preference (Admin)
Preference (Guest)
User Defined Keys (Current)
User Defined Keys (Admin)
User Defined Keys (Guest)
Custom Fader Bank (Current)
Custom Fader Bank (Admin)
Custom Fader Bank (Guest)
User Level (Current)
User Level (Guest)
*1) 0-300 Scene Number (0 Request Only),
*2) 1-199 Input EQ Library Number (1-40 Request Only)
*3) 1-199 Output EQ Library Number (1-3 Request Only)
*4) 1-199 Dynamics Library Number (1-41 Request Only)
*5) 0-199 GEQ Library Number (0 Request Only)
*6) 1-199 Effect Library Number (1-27 Request Only)
*7) 512-583 Input 1-72,
*8) 584-599 STIN 1L-8R,
*9) 768-791 MIX 1-24,
*10) 1024-1031 MATRIX 1-8,
*11) 1280-1282 STEREO L-C,
*12) 512-530 GEQ 1-19, 531-538 EFFECT GEQ 1-8,
*13) 0-199 8BandPEQ Library Number (0 Request Only)
*14) 512-519 EFFECT 1-8,
*15) 512 Current Data,
*16) 768 Current Data with Recall Safe,
rx/tx
Function
*17) 8192 Store Undo Data, 8193 Recall Undo Data, 8194 Clear Undo Data,
BULK DUMP DATA
*18) 0-199 Input CH Library Number (0 Request Only),
rx/tx
*19) 0-199 Output CH Library Number (0 Request Only),
*20) 512-527 Premium Rack 1A, 1B, 2A, ... 8A, 8B
BULK DUMP REQUEST
*21) 0-100 Each Premium Effect Library Number (0 Request Only)
*22) 1536-1607 Input 1-72 (for Dynamics2),
*23) 1608-1623 STIN 1L-8R (for Dynamics2),
*24) 0-10 Dante Input Patch Library Number (0 Request Only)
Data Number(dd)
*1) *15) *16) *17)
Data is lost when you write to the preset library.
*2) *7) *8)
The unique header (Model ID) identifies whether the device is a CL series.
To calculate the check sum, add the bytes starting with the byte after BYTE
*3) *9) *10) *11)
COUNT (LOW) and ending with the byte before CHECK SUM, take the binary
*4) *7) *8) *9) *10) *11) *22) *23)
complement, and set bit 7 to 0.
*18) *7) *8)
CHECK SUM = (-sum)&0x7F
*19) *9) *10) *11)
Bulk Dumps can be received at any time, and can be transmitted at any time
*5) *12)
when a Bulk Dump Request is received.
*13)
A Bulk Dump is transmitted on the [Rx CH] channel in response to a Bulk Dump
*6) *14)
Request.
In the data portion, seven words of 8-bit data are converted into eight words of
*20)
7-bit data.
*21)
Data Number(dd)
"P5043___"
*21)
"U76_____"
*21)
"OPT-2A__"
*21)
"EQ-1A___"
*21)
"DYNAEQ__"
*21)
"BSCMP369"
*21)
"DANTEIN_"
*24)
"MIXERSET"
Fix (512)
"OUT_PORT"
Fix (512)
"MONITOR_"
Fix (512)
"MIDI_SET"
Fix (512)
"LIB_NUM_"
Fix (512)
"PRGMCHG_"
Fix (512)
"CTRLCHG_"
Fix (512)
"PREF_CUR"
Fix (512)
"PREF_ADM"
Fix (512)
"PREF_GST"
Fix (512)
"UDEF_CUR"
Fix (512) include Knob, Encoder
"UDEF_ADM"
Fix (512) include Knob, Encoder
"UDEF_GST"
Fix (512) include Knob, Encoder
"CFAD_CUR"
Fix (512)
"CFAD_ADM"
Fix (512)
"CFAD_GST"
Fix (512)
"UKEY_CUR"
Fix (512)
"UKEY_GST"
Fix (512)
Data List

Werbung

Kapitel

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Cl3Cl1

Inhaltsverzeichnis