SERVICING
Warning! Mortal Danger!
Energised unit parts can cause death and severe
burns via electric shock.
- Switch off the central vacuum unit and pull the
power plug before performing maintenance.
- Only clean central vacuum unit with a dry cloth.
Service table
Component
1)
Waste container
1)
Cartridge filter
Unit motor
1)
2)
Suction hose
(with integrated transmitter)
Suction sockets and Vac-Pan
1)
With radio operation or operation via a control cable
2)
With radio operation
32
Servicing work
Empty/clean.
Clean: change if.
necessary.
Visual inspection of
carbon brushes,
replace if necessary.
Change battery.
1)
Check and clean.
The motor does not need to be lubricated due to its
construction type.
Increased use of the system may require shorter
service intervals.
Service interval
Seasonally
Semi-annually or
30 operating hours
Annually
When necessary
If soiled
Description
see Page 33
see Page 33
see Page 34
see Page 35