Safety rules

The personnel carrying out the installation, commis-
sioning, maintenance or repair of the device must be
properly qualified for this type of work. In particular,
the persons concerned must
- be suitably trained and familiar with handling
compressed-air systems besides being informed
about the associated dangers,
- know the content of the relevant instructions for
installation and operation, and
- possess vocational qualifications or entitlements
in this particular field of work.
Before the start of any work, the housing must first
be depressurized.
To ensure safe functioning, only use the device within
the operational limits (operating pressure, operating
temperature, volumetric flow, material stability).
As regards the model including a manual outlet valve
(needle valve), an additional diaphragm is installed
at the outlet side so as not to produce a sudden
pressure drop when opening and not to endanger
persons or other devices. The operator of the plant
assumes responsibility for the condensate discharge
which must be effected on a regular basis. In the case
of non-compliance, other plant components may be
damaged by condensate.
In the event of leaks, shut off the compressed-air
supply immediately and eliminate the cause in order
to maintain safe and cost-effective operation.
CLEARPOINT filters, including accessories, must
be checked once a week. This applies in particular
to the function of the separator.
For connections or joints only use suitably threaded
fittings designed for this pressure range, see page 18,
20, 22.
CLEARPOINT HP 100 S040-M020, HP 350 S030-M015, HP 500 S030-S050
english
Areas of application of filter
CLEARPOINT filters are designed for the separation of
solid particles, aerosols, oil vapours and odours from
non-aggressive compressed air or industrial gases.
Depending on the specific application, the filter housings
are provided with different inserts:
C Coarse filter for the separation of coarse solid matter
pollutants up to 25 µm.
G General purpose filter element for the separation of
large dirt particles up to 5 µm.
F
Fine filter element for the separation of liquids up to
0.1 mg/m³ and solid particles up to 1 µm.
S Super fine filter element for the separation of liquids
up to 0.01 mg/m³ and solid particles up to 0.01 µm.
N Nano filter element for the separation of liquids up
to 0.005 mg/m³ and solid particles up to 0.01 µm.
A Activated carbon filter elements for the separation
of oil vapours up to 0.003 mg/m³ and odours.
R(x) Dust filters for the separation of particles, fineness
from C to N
Limits in usage: see Technical data, page 18, 20, 22.