Anleitung DSS 260-2 SPK1
GB
the working pressure.
Never use oxygen or combustible gases as an
energy source.
Always disconnect the tool from the air supply
before carrying out any repairs or maintenance
work.
Use only original replacement parts.
Never allow the tool to run unloaded at full idle
speed for any length of time.
Wear the necessary protective clothing when
working with the impact screwdriver.
Wear ear-muffs and safety gloves!

5. Putting into operation

Screw the plug-in nipple included in delivery into the
air connection, having first wrapped 2 - 3 layers of
sealing tape around the thread. Attach the required
drive socket/bit to the square drive mount. Adjust the
direction of rotation on the guide lever.
R = reverse/release screw, F = forward/tighten
screw. Place the drive socket or bit on the nut or
screw head. Press the trigger. The air supply can be
adjusted by simultaneously depressing and turning
the air regulator. Mark 4 = max. torque, mark 1 =
min. torque. The tool is connected to the air supply
by means of a flexible pneumatic hose with a quick-
release coupling. To get the best performance out of
your screwdriver, use a pneumatic hose with an
internal diameter of LW 8 mm.

6. Maintenance and cleaning

Observance of the following maintenance
instructions will ensure that this quality tool gives you
years of troublefree service. Regular lubrication is
vital for the long-term, reliable operation of your
impact screwdriver. Use only special tool oil for this
purpose. You can choose from the following options
for lubricating the tool:
6.1 By mist oiler
A complete conditioning unit includes a mist oiler and
is fitted to the compressor.
6.2 By hand
Each time before you use your impactscrewdriver,
feed 3-5 drops of special tool oil into the air
connection. If the pneumatic tool has not been used
for several days, you must feed 5-10 drops of oil into
the air connection before you switch on. Keep your
pneumatic tool in dry rooms only.
6
13.07.2006
10:14 Uhr
Seite 6
7. Accessories
Special oil for pneumatic
tools 500 ml
8. The warranty does not cover:
Wearing parts
Damage caused by an unacceptable level of
working pressure.
Damage caused by unconditioned compressed
air.
Damage caused by improper use or unauthorized
tampering.

9. Ordering replacement parts

Please quote the following data when ordering
replacement parts:
Type of machine
Article number of the machine
Identification number of the machine
Replacement part number of the part required
For our latest prices and information please go to
www.isc-gmbh.info
Art. No. 41.383.10

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

41.389.10

Inhaltsverzeichnis