Herunterladen Inhalt Inhalt Diese Seite drucken

Yamaha QL1 Referenzhandbuch Seite 258

Vorschau ausblenden Andere Handbücher für QL1:
Inhaltsverzeichnis

Werbung

4.8
FUNCTION CALL – CHANNEL –
4.8.1 Pair ON/OFF Trigger Format (PARAMETER CHANGE)
Reception
Data will be received when [PARAMETER CHANGE Rx] is on and the Device
number of both [Rx CH] and SUB STATUS match.
The data will be echoed when [PARAMETER CHANGE ECHO] is on.
System exclusive message
STATUS
11110000 F0
Manufacture's ID number (YAMAHA)
ID No.
01000011 43
n=0-15 (Device number=MIDI Channel)
SUB STATUS
0001nnnn 1n
Digital mixer
GROUP ID
00111110 3E
QL Series
MODEL ID
00010010 19
DATA CATEGORY 00000000 00
OTHER DATA
FUNCTION NAME 01000011 "C"
01101000 "h"
01101100 "l"
01010000 "P"
01101001 "i"
01110010 "r"
01000011 "C"
01110000 "p"
(ASCII CODE)
MODULE NAME
0mmmmmmm mm
(ASCII CODE)
0mmmmmmm mm
(ASCII CODE)
0mmmmmmm mm
0mmmmmmm mm
(ASCII CODE)
(ASCII CODE)
0mmmmmmm mm
0mmmmmmm mm
(ASCII CODE)
(ASCII CODE)
0mmmmmmm mm
(ASCII CODE)
0mmmmmmm mm
Source Channel Number H *1)
DATA
0sssssss sh
Source Channel Number L *1)
0sssssss sl
0ddddddd dh
Destination Channel Number H *1)
Destination Channel Number L *1)
0ddddddd dl
End of exclusive
EOX
11110111 F7
4.8.2 Module Name
Module Name
Pair On (with Copy)
"PAIRONCP"
Pair On (with Reset Both)
"PAIRONRS"
Pair Off
"PAIROFF_"
*1)
0 : CH1
– 63: CH64
256 : MIX 1
– 271: MIX 16
512 : MATRIX 1 – 519: MATRIX 8
4.9 LEVEL METER DATA
4.9.1 Format (PARAMETER CHANGE)
When transmission is enabled by receiving Request for Level Meter, the
corresponding metering data will be sent in every 50 millisecond for 10 seconds.
If metering information is expected to be continuously sent, Request is needed to
be sent in at least every 10 seconds.
Reception
The data will be echoed when [PARAMETER CHANGE ECHO] is on.
Transmission
When transmission is enabled by receiving Request, the corresponding metering
data will be sent in constant interval for a given period of time (The interval and
time will vary depending on devices).
When rebooted or port setting is changed, the transmission will be disabled.
When [PARAMETER CHANGE ECHO] is on, the message will be sent as it is.
STATUS
11110000 F0
System exclusive message
Manufacture's ID number (YAMAHA)
ID No.
01000011 43
n=0-15 (Device number=MIDI Channel)
SUB STATUS
0001nnnn 1n
Digital mixer
GROUP ID
00111110 3E
QL Series
MODEL ID
00010010 19
REMOTE LEVEL METER
DATA CATEGORY 00100001 21
ADDRESS UL
DATA
0mmmmmmm mm
0mmmmmmm mm
ADDRESS LU
ADDRESS LL
0mmmmmmm mm
Data1
0ddddddd dd
:
:
End of exclusive
EOX
11110111 F7
4.9.2 Format (PARAMETER REQUEST)
Reception
Data will be received when [PARAMETER CHANGE Rx] is on and the Device
number of both [Rx CH] and SUB STATUS match.
The data will be echoed when [PARAMETER CHANGE ECHO] is on.
The corresponding metering data will be sent via [Rx CH] in constant interval for
a given period of time (The interval and time will vary depending on devices).
When Address UL = 0x7F is received, all metering data transmission will be
immediately stopped [disabled].
Transmission
When [PARAMETER CHANGE ECHO] is on, the message will be sent as it is.
System exclusive message
STATUS
11110000 F0
Manufacture's ID number (YAMAHA)
ID No.
01000011 43
n=0-15 (Device number=MIDI Channel)
SUB STATUS
0011nnnn 3n
Digital mixer
GROUP ID
00111110 3E
MODEL ID
00010010 19
QL Series
REMOTE LEVEL METER
DATA CATEGORY 00100001 21
ADDRESS UL
DATA
0mmmmmmm mm
ADDRESS LU
0mmmmmmm mm
ADDRESS LL
0mmmmmmm mm
Count H
0ccccccc ch
Count L
0ccccccc cl
EOX
11110111 F7
End of exclusive
39
Data List

Werbung

Kapitel

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Ql5

Inhaltsverzeichnis