Herunterladen Inhalt Inhalt Diese Seite drucken

Yamaha QL1 Referenzhandbuch Seite 253

Vorschau ausblenden Andere Handbücher für QL1:
Inhaltsverzeichnis

Werbung

2 SYSTEM REALTIME MESSAGE
2.1 SONG SELECT
Reception
Select the track number shown in the TITLE LIST screen of the USB memory recorder.
Song select
STATUS
11110011 F3
Song number (0-127)
Song number 0sssssss ss
2.2 TIMING CLOCK
Reception
This message is used to control effects. This message is transmitted twenty-four
times per quarter note.
Echoing of this message depends on the OTHER item in the ECHO settings.
Timing clock
STATUS
11111000 F8
2.3 ACTIVE SENSING
Reception
Once this message has been received, MIDI communication will be initialized (e.g.,
Running Status will be cleared) if no message is received for an interval of 400 ms.
This message is not subject to echoing.
STATUS
11111110 FE
Active sensing
2.4 SYSTEM RESET
Reception
When this message is received, MIDI communication will be initialized (e.g.,
Running Status will be cleared).
This message is not subject to echoing.
System reset
STATUS
11111111 FF
3 SYSTEM EXCLUSIVE MESSAGE
3.1 MMC
< MMC STOP >
Reception
If the [DEVICE NO.] matches or is 7F, receives this message and stops.
System exclusive message
STATUS
11110000 F0
Real time System exclusive
ID No.
01111111 7F
Destination (00-7E, 7F:all call)
Device ID
0ddddddd dd
COMMAND
00000110 06
Machine Control Command(MCC) sub-id
Stop(MCS)
00000001 01
End of exclusive
EOX
11110111 F7
< MMC PLAY >
Reception
If the [DEVICE NO.] matches or is 7F, receives this message and starts playback.
System exclusive message
STATUS
11110000 F0
Real time System exclusive
ID No.
01111111 7F
Destination (00-7E, 7F:all call)
Device ID
0ddddddd dd
COMMAND
00000110 06
Machine Control Command(MCC) sub-id
Play(MCS)
00000010 02
End of exclusive
EOX
11110111 F7
< MMC DEFERED PLAY >
Reception
(F3)
If the [DEVICE NO.] matches or is 7F, receives this message and starts playback.
System exclusive message
STATUS
11110000 F0
Real time System exclusive
ID No.
01111111 7F
Device ID
0ddddddd dd
Destination (00-7E, 7F:all call)
Machine Control Command(MCC) sub-id
COMMAND
00000110 06
Deferred Play(MCS)
00000011 03
End of exclusive
EOX
11110111 F7
(F8)
< MMC RECORD STROBE >
Reception
If the [DEVICE NO.] matches or is 7F, receives this message, and if stopped, starts
recording.
System exclusive message
STATUS
11110000 F0
Real time System exclusive
ID No.
01111111 7F
Destination (00-7E, 7F:all call)
Device ID
0ddddddd dd
(FE)
Machine Control Command(MCC) sub-id
COMMAND
00000110 06
Record strobe
00000110 06
End of exclusive
EOX
11110111 F7
< MMC PAUSE >
Reception
If the [DEVICE NO.] matches or is 7F, receives this message, and if playing, pauses.
System exclusive message
(FF)
STATUS
11110000 F0
Real time System exclusive
ID No.
01111111 7F
Destination (00-7E, 7F:all call)
Device ID
0ddddddd dd
Machine Control Command(MCC) sub-id
COMMAND
00000110 06
Pause(MCS)
00001001 09
EOX
11110111 F7
End of exclusive
3.2 BULK DUMP
This message is used to send or receive the contents of various memories stored
within the unit.
The basic format is as follows.
Command
F0 43 0n 3E cc cc 19 mm ... mm dd
dd ... ee F7
F0 43 2n 3E 19 mm ... mm dd dd F7 rx
The QL series console uses the following data types for a bulk dump.
Module Name(mm)
SCENE LIB
"SCENE___"
INPUT EQ LIB
"INEQ____"
OUTPUT EQ LIB
"OUTEQ___"
Dynamics LIB
"DYNA____"
INPUT CH LIB
"INCHNNL_"
OUTPUT CH LIB
"OUTCHNNL"
GEQ LIB
"GEQ_____"
EFFECT LIB
"EFFECT__"
Premium Effect
"PEFFECT_"
Portico5033 LIB
"P5033___"
Portico5043 LIB
"P5043___"
U76 LIB
"U76_____"
Opt-2A LIB
"OPT-2A__"
34
Module Name(mm)
EQP-1A LIB
DynamicEQ LIB
Dante Input Patch LIB
Mixer Setup
Outport Setup
Monitor Setup
MIDI Setup
Lib Number
Program Change Table
Control Change Table
Preference (Current)
Preference (Admin)
Preference (Guest)
User Defined Keys (Current)
User Defined Keys (Admin)
User Defined Keys (Guest)
Custom Fader Bank (Current)
Custom Fader Bank (Admin)
Custom Fader Bank (Guest)
User Level (Current)
User Level (Guest)
*1) 0–300 Scene Number (0 Request Only),
*2) 1–199 Input EQ Library Number (1–40 Request Only)
*3) 1–199 Output EQ Library Number (1–3 Request Only)
*4) 1–199 Dynamics Library Number (1–41 Request Only)
*5) 0–199 GEQ Library Number (0 Request Only)
*6) 1–199 Effect Library Number (1–27 Request Only)
*7) 512–583 Input 1-64,
*8) 584–599 STIN 1L-8R,
*9) 768–791 MIX 1-16,
*10) 1024–1031 MATRIX 1-8,
*11) 1280–1282 STEREO L-C,
*12) 512–530 GEQ 1–19, 531–538 EFFECT GEQ 1–8,
*13) 512–519 EFFECT 1–8,
*14) 512 Current Data,
*15) 768 Current Data with Recall Safe,
*16) 8192 Store Undo Data, 8193 Recall Undo Data, 8194 Clear Undo Data,
rx/tx
Function
*17) 0–199 Input CH Library Number (0 Request Only),
rx/tx
BULK DUMP DATA
*18) 0–199 Output CH Library Number (0 Request Only),
*19) 512–527 Premium Rack 1A, 1B, 2A, ... 8A, 8B
BULK DUMP REQUEST
*20) 0–100 Each Premium Effect Library Number (0 Request Only)
*21) 1536–1607 Input 1–64 (for Dynamics2),
*22) 1608–1623 STIN 1L–8R (for Dunamics2),
*23) 0-10 Dante Input Patch Library Number (0 Request Only)
Data Number(dd)
*1) *14) *15) *16)
Data is lost when you write to the preset library.
*2) *7) *8)
The unique header (Model ID) identifies whether the device is a QL series.
*3) *9) *10) *11)
To calculate the check sum, add the bytes starting with the byte after BYTE
*4) *7) *8) *9) *10) *11) *21) *22)
COUNT (LOW) and ending with the byte before CHECK SUM, take the binary
*17) *7) *8)
complement, and set bit 7 to 0.
CHECK SUM = (-sum)&0x7F
*18) *9) *10) *11)
*5) *12)
Bulk Dumps can be received at any time, and can be transmitted at any time
*6) *13)
when a Bulk Dump Request is received.
*19)
A Bulk Dump is transmitted on the [Rx CH] channel in response to a Bulk Dump
*20)
Request.
*20)
In the data portion, seven words of 8-bit data are converted into eight words of
7-bit data.
*20)
*20)
Data Number(dd)
"EQ-1A___"
*20)
"DYNAEQ__"
*20)
"DANTEIN_"
*23)
"MIXERSET"
Fix (512)
"OUT_PORT"
Fix (512)
"MONITOR_"
Fix (512)
"MIDI_SET"
Fix (512)
"LIB_NUM_"
Fix (512)
"PRGMCHG_"
Fix (512)
"CTRLCHG_"
Fix (512)
"PREF_CUR"
Fix (512)
"PREF_ADM"
Fix (512)
"PREF_GST"
Fix (512)
"UDEF_CUR"
Fix (512) include Knob, Encoder
"UDEF_ADM"
Fix (512) include Knob, Encoder
"UDEF_GST"
Fix (512) include Knob, Encoder
"CFAD_CUR"
Fix (512)
"CFAD_ADM"
Fix (512)
"CFAD_GST"
Fix (512)
"UKEY_CUR"
Fix (512)
"UKEY_GST"
Fix (512)
Data List

Werbung

Kapitel

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Ql5

Inhaltsverzeichnis