Herunterladen Inhalt Inhalt Diese Seite drucken

Storage; Electrical Connection - Parkside PZKS 1500 B2 Originalbetriebsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Storage/Electrical connection
or if the spring or contact wire are burned
or damaged, it is necessary to replace both
brushes. If the brushes are found to be
usable following removal, it is possible to
reinstall them.

11. Storage

Store the device and its accessories in
a dark, dry and frost-proof place that is
inaccessible to children. The optimum
storage temperature is between 5 and 30°C.
Store the electrical tool in its original
packaging.
Cover the electrical tool in order to protect it
from dust and moisture.
Store the operating manual with the electrical
tool.

12. Electrical connection

The electrical motor installed is connected
and ready for operation. The connection
complies with the applicable VDE and DIN
provisions.
The customer's mains connection as well as
the extension cable used must also comply
with these regulations.
• The product meets the requirements of
EN 61000-3-11 and is subject to special
connection conditions. This means that
use of the product at any freely selectable
connection point is not allowed.
• Given unfavorable conditions in the
power supply the product can cause the
voltage to fluctuate temporarily.
• The product is exclusively intended for
use at connection points that have a
continuous current-carrying capacity of at
least 100 A per phase.
• As the user, you are required to ensure,
in consultation with your electric power
company if necessary, that the connection
point at which you wish to oper-ate the
product meets the specified requirements.
Damaged electrical connection cable
The insulation on electrical connection cables
is often damaged.
This may have the following causes:
• Passage points, where connection cables
are passed through windows or doors.
• Kinks where the connection cable has
been improperly fastened or routed.
• Places where the connection cables have
been cut due to being driven over.
• Insulation damage due to being ripped
out of the wall outlet.
• Cracks due to the insulation ageing. Such
damaged electrical connection cables
must not be used and are life-threatening
due to the insulation damage.
Check the electrical connection cables
for damage regularly. Make sure that the
connection cable does not hang on the
power network during the inspection.
Electrical connection cables must comply
with the applicable VDE and DIN provisions.
Only use connection cables with the marking
"H05VV-F".
The printing of the type designation on the
connection cable is mandatory.
AC motor
• The mains voltage must be 230 V~
• Extension cables up to 25 m long must
have a cross-section of 1.5 mm².
Connections and repairs of electrical
equipment may only be carried out by an
electrician.
Please provide the following information
in the event of any enquiries:
• Type of current for the motor
• Machine data - type plate
GB / IE / NI
37

Quicklinks ausblenden:

Werbung

Kapitel

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

280657

Inhaltsverzeichnis