INSTALLATION
After unpacking the product, check for any damage during transport. In case of problems, contact the dealer or the After-Sales Service.
PREPARING THE CABINET FOR FITTING
WARNING
The distance between the underside of the appliance and the separator panel must respect the dimensions given in the figure.
In order to ensure the correct operation of the product, do not obstruct the minimum required clearance between the hob and the top of the unit (min. 5 mm).
If an oven is installed beneath the hob, make sure the oven is equipped with a cooling system.
Do not install the hob above a dishwasher or washing-machine, so that the electronic circuits do not come into contact with steam or moisture which could
damage them.
To remove the hob from the worktop use a screw driver (not supplied) unlocking the springs from the bottom side of the appliance.

ELECTRICAL CONNECTION

WARNING
-
The manufacturer declines all liability for injury to persons or animals and for damage to property resulting from failure to observe the
regulations provided in this chapter.
-
The power cable must be long enough to allow the hob to be removed from the worktop.
-
Make sure the voltage specified on the dataplate located on the bottom of the appliance is the same as that of the home.
Connection to the terminal block
For the electrical connection, use an H05RR-F cable as specified in the table below.
Wires
Number x size
230 V ~ +
3 X 4 mm
3 X 4 mm
230-240 V ~ +
(3X2.5 mm
230 V 3 ~ +
4 x 1.5 mm
400 V 3N ~ +
5 x 1.5 mm
400 V 2N ~ +
4 x 1.5 mm
A
B
Important:
- Based on the wiring diagram (see figure) either keep or remove the metal
jumpers between the screws on the terminal block L1-L2 and N1-N2.
- Make sure all six screws on the terminal block are tightened after
connecting the cables.
-Example of jumper present (left) or removed (right). See the wiring diagram
for details (the jumpers can be between L1-L2 and between N1-N2).
-
Install a separator panel under
the hob.
-
The lower part of the product
must not be accessible after
installation.
-
In case of installation of an
undertop oven, do not interpose
the separator panel.
-
Disconnect the appliance from the power supply.
-
Installation must be carried out by qualified personnel who know the current safety and
installation regulations.
2
(3X2.5 mm
2
Domino)
(Australia only)
2
Domino)
2
2
2
2
C
DOMINO
GB12
230-240 V ~ (Australia only)
230 V ~
400 V 3N ~
400 V 2N ~
230 V 3 ~ (Belgium only)
400 V 2N ~ (Holland only)
min 20 mm
min 5 mm
230 V ~ (UK only)