Total vibration values (vector sum of three direc-
tions) determined in accordance with EN 60745.
Vibration emission value a
K uncertainty = 1.5 m/s
Warning!
The specifi ed vibration value was established in
accordance with a standardized testing method. It
may change according to how the electric equip-
ment is used and may exceed the specifi ed value
in exceptional circumstances.
The specifi ed vibration value can be used to
compare the equipment with other electric power
tools.
The specifi ed vibration value can be used for initi-
al assessment of a harmful eff ect.
Keep the noise emissions and vibrations to a
minimum.
Only use appliances which are in perfect wor-
king order.
Service and clean the appliance regularly.
Adapt your working style to suit the appliance.
Do not overload the appliance.
Have the appliance serviced whenever ne-
cessary.
Switch the appliance off when it is not in use.
Wear protective gloves.
Residual risks
Even if you use this electric power tool in
accordance with instructions, certain resi-
dual risks cannot be rules out. The following
hazards may arise in connection with the
equipment's construction and layout:
1. Lung damage if no suitable protective dust
mask is used.
2. Damage to hearing if no suitable ear protec-
tion is used.
3. Health damage caused by hand-arm vib-
rations if the equipment is used over a pro-
longed period or is not properly guided and
maintained.
Anl_TH_MA_1300_SPK1.indb 15
Anl_TH_MA_1300_SPK1.indb 15
GB

5. Before starting the equipment

Before you connect the equipment to the mains
≤ 2.5 m/s
2
supply make sure that the data on the rating plate
h
2
are identical to the mains data.
Always pull the power plug before making adjust-
ments to the equipment.
5.1 Setting the groove depth (Fig. 1)
Slacken the locking screw (6).
Set the depth stop (7) to the desired depth.
Tighten the locking screw (6).
5.2 Fitting the vacuum extractor unit adapter
(Fig. 3/4)
Important! For health safety reasons it is impe-
rative that you use a vacuum extractor unit. The
extractor socket is suitable for use on vacuum ex-
tractor units (vacuum cleaners). The extractor unit
must be suitable for the extraction of fi ne dust.
Slot the pins on the vacuum extractor unit
adapter (9) into the recesses on the extractor
connection (a).
Turn the adapter (9).
Unscrew the cap (b).
Insert the vacuum extractor unit hose well into
the opening on the adapter (9).
Tighten the cap (b) until the hose is held firm-
ly in place.
5.3 Trial run for new diamond cutting wheels
Have the equipment run in idle mode for at least
1 minute with the cutting wheels fi tted. Replace
vibrating wheels immediately.

6. Operation

6.1 Switch (Fig. 5)
The equipment comes with a safety switch which
is designed to prevent accidents.
To start the equipment, push the locking lever (5)
forwards and then press the ON/OFF switch (4).
Wait until the machine has reached its top
speed.
6.2 Changing and setting the diamond cut-
ting wheels (Fig. 6-11)
Important! Pull the mains power plug from the
socket-outlet.
Remove the handle (8).
Remove the screws (a) and the locking screw
- 15 -