START-UP
You receive a completely assembled magnetic core drilling machine and detailed operation manual.
Please check the condition of the goods on receipt for any transport damage, and make sure the delivery is
complete. Otherwise contact the manufacturer immediately.
!
Vor dem ersten Gebrauch unbedingt die Bedienungsanleitung lesen!
1.
First of all, check the cables and connectors for damages.
2. Plug the safety switch connector into a fused mains socket.
3. Before starting the core drilling machine motor, be sure to press the RESET button to activate the safety
switch. Repeat this step every time you pull the mains plug and every time the safety switch triggers.
4. Insert the core drill in the tool holder on the working spindle of the motor and check the stable, exactly
positioned clamping of the tool (see back).
5. The lever is pointing upwards and the switchable permanent magnet is deactivated so that you
can position the machine. A slight magnetic pre-tension helps with alignment of the machine on
vertical walls or for overhead work.
• If you are working on non-magnetic materials, please use the ROTABEST Vacubest vacuum
equipment (part no. 18150).
6. Secure Rotabest with a strap when holding the machine vertically up against the wall or ceiling. During
these applications, best practice is to cool the drill bit with a spray (e.g. ALFRA 4000, part no. 21040).
7. Press the lever down as far as it will go. Make sure that the safety tab audibly latches into place.
8. As soon as the sensor LED lights up green or flashes red, activate the motor by
pressing the MOTOR ON key on the operating panel at the side.
9. Repeat the above step to switch the motor off: First of all, press the red button
(Motor) to switch off the motor, then press the Solenoid button to deactivate
the solenoid.To deactivate the permanent magnet, press the black safety tab
inwards using the ball of your hand and lift the lever up.
16
Do not use the safety switch as an On/Off switch!