Contacts COMMON and EVAC connected:
the alarm signal is converted into a rising
siren signal
Contacts EMC IN and GND for an (emergency)
signal taking priority over other signals:
As soon as a signal is present at these con-
tacts, it will be routed to all zones . Other
signals will be interrupted and the indication
"AL" will flash on the displays (3) . The signal
volume can be adjusted with the control
EMC INPUT (32) .
31 Control TONE OUTPUT for the volume of
the alarm signal
32 Control EMC INPUT for the volume of the
signal at the contact EMC IN of the terminal
EMERGENCY (30)
33 D-Sub connections (DC-37) to interconnect
several units ARM-880 to obtain additional
PA zones (max . 32),
chapter 4 .7
34 Stereo inputs LINE 1 – 4 for connection of
audio units with line output (e . g . radio,
MP3 / CD player, tape deck)
35 Control GAIN for input level matching of
the inputs LINE 1 – 4
36 Audio inputs LINE / MIC 5 – 8 for connection
of audio units with line output or for con-
nection of microphones
37 Selector switch for the inputs LINE / MIC
5 – 8
LINE = for an audio unit with line output
MIC = for a microphone
PHANTOM = for a microphone requiring a
phantom power (46 V)
38 RJ45 jacks PAGING MIC 1 and 2 for
con nection of two zone paging micro-
phones ARM-880RC
39 Control GAIN for the sensitivity of the in-
puts PAGING MIC 1 and 2 (38)
40 Jack MICROPHONE 1 for a microphone
The microphone signal can be heard in all
zones: to be adjusted with the controls
MIC 1 (6)
41 Control GAIN for the sensitivity of the input
MICROPHONE 1 (40)
42 Tone controls HF (high frequencies) and LF
(low frequencies) for the microphone con-
nected to the jack (40)

1.3 Accessories

The units of the figures 2 to 6 are available
as accessories and are not supplied with the
matrix router ARM-880 .

1.3.1 ARM-880RC and ARM-880RCE

Zone paging microphone and extension module
43 Switch CHIME
2-TONE = 2-tone chime when pressing the
button TALK (52)
OFF
= no chime
4-TONE = 4-tone chime
44 Control CHIME for the chime volume
45 Control MIC for the microphone volume
46 Jack CONNECT TO ARM-880 for connec-
tion of the microphone to the jack PAGING
MIC 1 or 2 (38)
47 Jack 24 V⎓ for connection of the power
supply unit provided
48 POWER switch
49 Connection cable for a possible extension
module ARM-880RCE (
50 DIP switches to address the extension
module
Switch 1 to ON for module 1
Switch 2 to ON for module 2
Switch 3 to ON for module 3
51 Jack MIC to insert the supplied gooseneck
microphone
52 Button TALK
53 Button ALL CALL for announcements in
all zones
54 Indication for the output level
55 POWER LED
56 Removable label to mark the zones
57 Buttons with indicating LED to activate the
zones intended for the announcement
58 Connection plug for the next extension
module

1.3.2 ARM-880WP1 and ARM-880WP2

Wall modules for remote control of a zone,
ARM-880WP1 in addition to the remote
feed-in of audio signals
59 RCA jacks LINE INPUT for feed-in of a line
signal which arrives at the corresponding
zone only
60 XLR jack MIC INPUT for connection of a
microphone* whose signals can only be
heard in the corresponding zone
61 Control LINE LEVEL for the volume of an
audio unit connected to the jacks LINE
INPUT (59)
62 Control MIC LEVEL for the volume of a
microphone connected to the jack MIC
INPUT (60)
63 Display to indicate the signal source
selected with the buttons SOURCE (64)
(also see item 3)
64 Buttons SOURCE to select the signal source
65 Power LED ON
66 Control SOURCE LEVEL for the zone volume
Adjust the corresponding control MASTER
(8) at the ARM-880 to the maximum ad-
missible zone volume .

1.3.3 ARM-880WP3

Wall module for feeding the signals of two
microphones to one zone
67 XLR jacks to connect two microphones*
68 Tone controls HF (high frequencies) and
LF (low frequencies) for the microphones
connected
69 Volume control for the microphones con-
nected
70 Button LINE MUTE: to mute the signal
source selected at the ARM-880 so that
only the microphone signals of the wall
module can be heard
71 Power LED ON

2 Safety Notes

The unit corresponds to all relevant directives
of the EU and is therefore marked with
WARNING The unit is supplied with haz-
chapter 4 .7)
The unit is suitable for indoor use only . Pro-
tect it against dripping water and splash
water, high air humidity and heat (admis-
sible ambient temperature range 0 – 40 °C) .
Do not place any vessels filled with liquid,
e . g . drinking glasses, on the unit .
Do not set the unit into operation, and im-
mediately disconnect the mains plug from
the mains socket if
1 . there is visible damage to the unit or to
the mains cable,
2 . a defect might have occurred after a drop
or similar accident,
3 . malfunctions occur .
The unit must in any case be repaired by
skilled personnel .
Never pull the mains cable to disconnect the
mains plug from the mains socket, always
seize the plug .
For cleaning only use a dry, soft cloth, never
use chemicals or water .
No guarantee claims for the unit and no li-
ability for any resulting personal damage or
material damage will be accepted if the unit
is used for other purposes than originally
intended, if it is not correctly connected or
operated, or not repaired in an expert way .
If the unit is to be put out of oper-
ation definitively, take it to a local
recycling plant for a disposal which
is not harmful to the environment .
* Caution! Do not connect any microphone with
unbalanced output . It may be damaged because a
15 V phantom power is always present at the jacks .
.
ardous mains voltage . Leave
servicing to skilled personnel
only . Inexpert handling or mod-
ification of the unit may cause
an electric shock hazard .
11

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis