FIT-AED-KIT
PC
COM1
USB
Connection:
Connect red wire with
the RED terminal
)
FIT
Fig.2: Connecting the FIT to the Starter KIT
The CANH_out and CANH _in and CANL_out and CANL_in ports respecti-
vely have been connected to each other in the FIT.
5
AED9401A and AD103C settings
These settings have to be made once in the AED9401A basic device and in
the AD103C.
AED9401A basic device settings (see operating manual):
Select CAN bus or DeviceNet (DIL switch)
D
CAN bus disconnection OFF
D
AD103C settings (default):
CAN bus address 63 / DeviceNet address 63
D
CAN baud rate 125000
D
Diagnosis address (ADR = 31, baud rate 38400)
D
AD103C settings can be changed using the AED_Panel32 (Version 3.x.x) Pa-
nel software.
A2022-1.0 de/en
Power
supply
24 V
DC
Cable
(SUB-D9)
PEAK-
Adaptor
Cable 1
CAN-Bus,
Diagnosis-Bus,
UB / GND, 8 wires
OUT1
OUT2
OUT3
OUT4
UB
GND
FIT
Kabel2/
cable 2
RED
RED
CAN+
CAN−
FIT
Kabel1/
RA/TA
cable 1
RB/TB
Cable 2
digital I/O, 8 wires
IN1
IN2
UB
GND
GND
OUT 1
OUT 1
OUT 2
OUT 2
OUT 3
OUT 3
OUT 4
OUT 4
IN1
IN1
IN2
IN2