Safety rules

• The personnel carrying out the installation, commis-
sioning, maintenance or repair of the device must be
properly qualified for this type of work. In particular,
the persons concerned must
- be suitably trained and familiar with handling
compressed-air systems besides being informed
about the associated dangers,
- know the content of the relevant instructions for
installation and operation, and
- prossess vocational qualifications or entitlements
in this particular field of work.
Before the start of any work, the housing must first
be depressurized.
In the case of CLEARPOINT filters with BEKOMAT
all the rules of the separate instructions need to be
complied with.
• To ensure safe functioning, only use the device within
the operational limits (operating pressure, operating
temperature, volumetric flow, material stability).
• Where a BEKOMAT is installed, it must be ensured
that the device is designed for the stated volumetric
flow of compressed air or gas. Condensate surges
into the device can impair the function.
• In the event of leaks, shut off the compressed-air
supply immediately and eliminate the cause in order
to maintain safe and cost-effective operation.
CLEARPOINT filters, including accessories, must
be checked once a week. This applies in particular
to the function of the separator.
CLEARPOINT S040 - M032
english

Areas of application

CLEARPOINT filters are designed for the separation of
solid particles, aerosols, oil vapours and odours from
non-aggressive compressed air or industrial gases.
Depending on the specific application, the filter housings
are provided with different inserts:
C Coarse filter for the separation of coarse solid matter
pollutants up to 25 µm.
G General purpose filter element for the separation of
large dirt particles up to 5 µm.
F
Fine filter element for the separation of liquids up to
0.1 mg/m³ and solid particles up to 1 µm.
S Super fine filter element for the separation of liquids
up to 0.01 mg/m³ and solid particles up to 0.01
µm.
N Nano filter element for the separation of liquids up
to 0,001 mg/m³ and solid particles up to 0,01 µm.
A Activated carbon filter elements for the separation
of oil vapours up to 0.003 mg/m³ and odours .
R(x) Dust filter for the separation of solid particles,
fineness from C to N
Max. operating pressure:
Max. operating temperature: +2 °C to +60 °C
Recommended operating temperature:
A: +2 °C ... +30 °C
to 16 bar
C, G, F, S, N: +2 °C ... +40 °C
R(x): +2 °C ... +60 °C