Safety rules

• The plant operator must put in place suitable technical
safety measures to ensure that the operating parame-
ters cannot be exceeded.
• The personnel carrying out the installation, commis-
sioning, maintenance or repair of the device must be
properly qualified for this type of work. In particular,
the persons concerned must
- be suitably trained and familiar with handling
compressed-air systems besides being informed
about the associated dangers,
- know the content of the relevant instructions for
installation and operation, and
- possess vocational qualifications or entitlements
in this particular field of work.
• Before the start of any work, the housing must first be
depressurized.
• In the case of CLEARPOINT water separators and
filters with BEKOMAT 12 PN 63 all the rules of the
separate instructions need to be complied with.
• To ensure safe functioning, only use the device within
the operational limits (operating pressure, operating
temperature, volumetric flow, material stability). Pres-
sure surges must be avoided.
• Where a BEKOMAT 12 PN 63 is installed, it must be
ensured that the device is designed for the stated
volumetric flow of compressed air or gas. Condensate
surges into the device can impair the function.
• In the event of leaks, shut off the compressed-air
supply immediately and eliminate the cause in order
to maintain safe and cost-effective operation.
• CLEARPOINT water separators and filters, including
accessories, must be checked once a week. This
applies in particular to the function of the separator.
When using water separators/filters with a manual
drain: be careful opening the ball valve (large opening
cross-section). Manual drains must be secured against
accidental opening.
• For connections or joints only use suitably threaded
fittings designed for this pressure range. (see page
18)
• CLEARPOINT wall brackets are designed for a ma-
ximum load of 3 filters in series. Any additional me-
chanical loads, e.g. due to pipes or other equipment,
must be avoided.
CLEARPOINT S040 - M023 HP 50
english
Areas of application of water separators
CLEARPOINT water separators are designed for the
separation of solid particles and liquid droplets from non-
aggressive compressed air or industrial gases.
Limits in usage
max. operating pressure :
max. operating temperature : +2°C to +60°C
Areas of application of filter
CLEARPOINT filters are designed for the separation of
solid particles, aerosols, oil vapours and odours from
non-aggressive compressed air or industrial gases.
Depending on the specific application, the filter housings
are provided with different inserts:
C Coarse filter for the separation of coarse solid matter
pollutants up to 25 µm.
G General purpose filter element for the separation of
large dirt particles up to 5 µm.
F
Fine filter element for the separation of liquids up to
0.1 mg/m³ and solid particles up to 1 µm.
S Super fine filter element for the separation of liquids
up to 0.01 mg/m³ and solid particles up to 0.01 µm.
N Nano filter element for the separation of liquids up
to 0.005 mg/m³ and solid particles up to 0.01 µm.
A Activated carbon filter elements for the separation
of oil vapours up to 0.003 mg/m³ and odours.
R(x) Dust filters for the separation of particles, fineness
from C to N
Limits in usage
Max. operating pressure:
Max. operating temperature: +2 °C to +60 °C
Recommended operating temperature:
50 bar
50 bar
C, G, F, S, N: +2°C bis +40 °C
A: +2°C bis +30 °C
7