trician to have the domestic installation ad-
apted.
Only use adapters and power cords ap-
proved by the manufacturer.
ATTENTION
Carrying the appliance by the door handle
could break it. The door handle cannot sup-
port the weight of the appliance.
Do not carry or hold the appliance by the
door handle.
¡ The safe operation of this appliance can only
be guaranteed if it has been installed to a
professional standard in accordance with
these installation instructions. The installer
shall be liable for damages incurred as a
result of incorrect installation.
¡ Check the appliance for damage after un-
packing it. Do not connect the appliance if it
has been damaged in transit.
¡ Before starting up the appliance, remove any
packaging material and adhesive film from
the cooking compartment and the door.
¡ Proceed in accordance with the installation
sheets for installing accessories.
¡ Fitted units must be heat-resistant up to
90 °C, and adjacent unit fronts up to 70 °C.
¡ Do not install the appliance behind a decor-
ative panel or unit door. There is a risk of
overheating.
¡ Cut-out work on the units should be carried
out before installing the appliance. Remove
any shavings. Otherwise, the correct opera-
tion of electrical components may be ad-
versely affected.
¡ The mains socket for the appliance must be
located outside of the area where the appli-
ance is installed.
19.4 Installing below a hob
If the appliance is installed below a hob, the following minimum dimensions must be adhered to (including substruc-
ture, if applicable).
The minimum worktop thickness
is determined by the required minimum clearance
¡ Always earth electrical appliances.
¡ Wear protective gloves so that you do not
cut yourself. Parts that are accessible during
installation may have sharp edges.
¡ Dimensions of the figures in mm.
19.2 Appliance dimensions
You will find the dimensions of the appliance here
19.3 Installation below a worktop
Observe the installation dimensions and the safety clear-
ances when installing below a worktop.
To ventilate the appliance, the intermediate floor must
have a ventilation cut-out.
Installation instructions en
.