Herunterladen Inhalt Inhalt Diese Seite drucken

N30Xx Series Installation; Site Preparation - Dell N20 serie Handbuch Zum Einstieg

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 134

N30xx Series Installation

Site Preparation

N30xx Series switches can be mounted in a standard 48.26 cm (19-inch) rack
or placed on a flat surface.
Make sure that the chosen installation location meets the following site
requirements:
Power — The switch is installed near an easily accessible 100–240 VAC,
50–60 Hz outlet.
Clearance — There is adequate front and rear clearance for operator
access. Allow clearance for cabling, power connections, and ventilation.
Cabling — The cabling is routed to avoid sources of electrical noise such
as radio transmitters, broadcast amplifiers, power lines, and fluorescent
lighting fixtures.
Ambient Temperature — The ambient switch operating temperature
range is 0 to 45ºC (32 to 113ºF) at a relative humidity of up to 95 percent,
non-condensing.
NOTE:
Decrease the maximum temperature by 1°C (1.8°F) per 300 m (985 ft.) above
900m (2955 ft.).
Relative Humidity — The operating relative humidity is 8% to 85%
(noncondensing) with a maximum humidity gradation of 10% per hour.
40
Getting Started Guide

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

N30 serie

Inhaltsverzeichnis