LED Indicator Status
Yellow light flash
Yellow light steady on
Green light flash (5s)
Green light flash (2s)
Red light flash (2s)
Red light steady on
About 10s after connection with DC power, the light turns yellow;
The yellow light flashes for 10s continuously and then keeps steady on which stands for microinverter self-check;
Afterwards, if the system is not powered on, the red light will flash, indicating for no grid existence;
After microinverter connects with DC power for the first time, red light flashes indicates for errors during microinverter
startup.
Microinverter startup. If the light flashes once in 1s, flashes in 10s or still flashes
after 10s, microinverter startup fails.
Microinverter standby/self-checking.
Normal operation; normal AC grid; communicating with routher.
Normal operation; normal AC grid; no connection with routher.
No AC grid or AC grid outside the regulatory range.
Error: non-grid abnormal fault. Machine fault like grounding detection fault and
PV side fault.
Description