Certificate No.:
IECEx TUN 14.0021X
Date of issue:
2024-12-19
EQUIPMENT:
Equipment and systems covered by this Certificate are as follows:
The LA36 series of linear actuators creates motion in a straight line, as contrasted with circular motion of a conventional electric motor. The
actuator consists of a motor, a gearbox and a spindle that causes the actuator to either extend or retract. The motor housing consists of a two-
part aluminium assembly with a cork gasket and an aluminium outer tube. The equipment is earthed externally through actuators fixation
points: the piston rod eye and the back fixture. The actuators are rated for 12V, 24V or 36V d.c. with push / pull specifications up to 10000 N.
odel LA36 can furthermore be delivered with an accessory, called
for mechanical fixing of a cable conduit, to make the power and signal cable rodent protected. This external cable gland has no influence on
the Ex-protection principle and the ingress protection is still kept IP6x.
The actuators are certified under the type LA36 including various type variants which has no influence on the ingress protection / Ex-
protection principle. The manufacturers
Supply (brown and blue)
U
Type 1
n
I
n
U
Type 2
n
I
n
U
Type 3
n
I
n
Signal Power suppy (red and black)
U
n
I
n
SPECIFIC CONDITIONS OF USE: YES as shown below:
1. The max. duty cycle is specified as follows at an ambient temperature of +25 C:
LOAD 0-6800 [N]
STROKE
0-600 [mm]
600-1000 [mm]
LOAD 10000 [N]
STROKE
0-1000 [mm]
2. Ambient temperature area is specified to -25 °C to + 65 °C
3. The power supply cable is of special design fulfilling IP 6X ingress protection. The cable can be delivered in different lengths. Only cables
delivered by LINAK A/S must be mounted.
IECEx Certificate
of Conformity
cheduled Drawings specify the fixed part of the construction.
12
V d.c.
22
A
=
24
V d.c.
=
11
=
36
V d.c.
=
A
=
12 - 24
V d.c.
=
40
mA
DUTY CYCLE
20% int. - Max. 2 [min.] continuous drive followed by 8 [min.] rest.
15% int. - Max. 3 [min.] continuous drive followed by 17 [min.] rest.
DUTY CYCLE
5% int. - Max. 1 [min.] continuous drive followed by 19 [min.] rest.
Page 3 of 5
Issue No: 2
odent protection . This variant is mounted with an external cable gland
+ 20%
+ 10%
+ 10%
LA36 | 53