DCV Reading Color Table
When the meter shows the value of DCV, the reading may be shown with the specified
color according to the following table.
Reading Color and its Range
4.000V to 4.500V
4.501V to 6.000V
6.001V to 7.500V
7.501V to 10.600V
< 10.600V
10.601V to 12.200V
12.201V to 12.500V
12.501V to 13.500V
13.501V to 13.900V
13.901V to 14.900V
14.901V to 15.500V
15.500V to 17.500V
>17.500V
< 21.301V
21.301V to 24.600V
24.601V to 25.000V
25.001V to 27.000V
27.001V to 27.900V
27.901V to 29.000V
29.001V to 31.000V
31.001V to 35.000V
35.001V to 37.500V
Action the repairer should take
< 4.00V : Normal Display
Check sensor connection
Sensor OK
Read the Service Manual
Read the Service Manual
Replace 12V battery
Recharge battery and test
Recharge 12V battery
12V Battery OK
Check alternator, loose belt etc.
12V Normal Alternator OK
12V Normal alternator : Check regulator.
12 Smart Alternator OK
Replace 24V battery
Check alternator / setting
Replace 24V battery
Recharge battery and test
Recharge 24V battery
24V Battery OK
Check alternator, loose belt etc.
24V Normal Alternator OK
Check regulator
24V Smart Alternator OK
Check alternator / setting
>37.500V : Normal Display