9.7 Setting operation timers
Set a timer to control for how long the hot air gun heats and maintains the set temperature. After the timer elapses,
the hot air gun switches to cooling mode.
Menu entry
/Ht
/Ht
1. Press and hold the settings buttons 1 and 3 at the same time until the display shows SET.
2. Navigate to the menu entry using the settings buttons 1 and 3.
3. Use the menu selector buttons TEMP to adjust the value.
4. Save the entry by pressing the settings button 2.
9.8 Calibrating temperature
If you have determined that the actual temperature that exits the nozzle deviates from the displayed temperature
(tD), calibrate the temperature using a temperature offset (Δt).
After you set the offset, the displayed temperature is tNew= tD + Δt.
Menu entry
/CAL
/CAL
/CAL
1. Press and hold the settings buttons 1 and 3 at the same time until the display shows SET.
2. Navigate to the menu entry using the settings buttons 1 and 3.
3. Use the menu selector buttons TEMP to adjust the value.
4. Save the entry by pressing the settings button 2.
9.9 Using default shortcuts
If the hor air gun is in operation, the settings buttons act as shortcuts. The hot air gun is programmed with three de-
fault shortcuts.
Shortcut button
1
2
3
You can use shortcuts in two ways:
■
Press a shortcut button and then lift the hot air gun from the hot air gun holder.
■
Lift the hot air gun from the hot air gun holder and then press a shortcut button.
Value
OFF
10...900
Value
-50...-01°C
-90...-01°F
-00°C
-00°F
01...50°C
01...90°F
Temperature
Cool
300 °C
400 °C
Description
Timer is off
Timer duration in seconds
Description
Negative temperature offset
Without temperature offset
Positive temperature offset
Airflow
50 %
50 %
50 %
33