7.2 Setting up the soldering iron

Important:
– Only connect the supplied soldering iron or a replacement soldering iron of identical type.
– You cannot adjust soldering iron settings if the soldering iron is disconnected. If the soldering iron is discon-
nected and the main unit switched on, the display shows S-E.
1. Connect the soldering iron to the soldering iron connection port.
2. Place the soldering iron into the soldering iron stand.

8 Global settings

Global settings apply to the hot air gun and the soldering iron.

8.1 Making global settings

You can perform global settings either via the hot air gun menu or the soldering iron menu.
1. Press and hold the settings buttons 1 and 3 at the same time until the display shows SET.
2. Navigate to the menu entry using the settings buttons 1 and 3.
3. Use the menu selector buttons TEMP to adjust the value.
4. Save the entry by pressing the settings button 2.

8.2 Available global settings

8.2.1 Button sound

Menu entry
/bL
/bL

8.2.2 Temperature unit

Menu entry
/C-F
/C-F

8.2.3 Password protection

Password protection protects user settings against modification and is useful if the product is used by multiple
users. The master password can unlock the menu in any case.
Menu entry
/Psd
/Psd
/Psd
30
Value
ON
OFF
Value
-°F
-°C
Value
---
906
001...905
Description
Sound on
Sound off
Description
Degrees Fahrenheit
Degrees Celsius
Description
No password protection
Master password:
The master password can unlock the menu. Use the
master password if you forgot your password.
Allocate users