Safety Instructions:

Non-compliance with the safety instructions can result in danger both to persons and to the
environment and the equipment. Non-compliance with the safety instructions can lead to the
loss of any claims for damages. The operator of the equipment must ensure that the
contents of the Operating Instructions, particularly the Safety Instructions are known to the
operating personal.
Always carefully read, thoroughly understand and follow the pump operating
instructions. Use this pump correctly and with care for the purpose for which it is
intended. Failure to do may cause damage or personal injury and will invalidate the
warranty. Retain instructions for future reference.
Contact your chemical or fluid supplier to check for compatibility with pump prior to
installation and operation.
Prior to use, always carefully and thoroughly read and understand the OSHA
information contained in the Safety Data Sheet supplied for the chemical which is to be
pumped.
Wear protective clothing (goggles, face masks, long sleeves, long pants, gloves,
aprons, etc.) as set forth in the OSHA Safety Data Sheet when pumping any hazardous
chemicals.
When using flammable liquids, pump containers should be grounded to avoid static
electricity.
Any pump used for transferring flammable liquids must be stored in a ventilated area
after use.
Pump should be washed out before it is used since processing lubricants may
contaminate the fluids.
Prior to use, inspect your pump thoroughly verifying its proper assembly.
If pump is removed from drum, it should be thoroughly rinsed in a liquid that is
compatible with both the pump and fluid.
Assemble and Installation
Check to see if all parts are included.
Screw discharge spout (Ref No. 9) into pump body (Ref No. 1) outlet using PTFE
sealant tape provided. Do not use pipe sealant.
In order to avoid leakage, please use Teflon tape provided to seal three suctions
tubes (Ref No. 20) with two tube connectors (Ref No. 21).
Insert the bung adapter (Ref No. 19) into suction tube assembled then screw
suction tubes assembled into pump inlet.
Insert handle shaft (Ref No. 17) through handle (Ref No. 16). Turn the hex nut
(Ref No. 18) onto handle shaft until handle rotates freely.
Screw handle assembled to crank arm (Ref No. 14). Keep handle shaft from
turning. Tighten hex nut (Ref No. 18) against crank arm. Then insert crank arm
assembly onto rotor (Ref No. 4), taking care to align set screw (Ref No. 15) to
indent in rotor shaft.
Insert pump assembled into drum and hand tighten the fixed screw (Ref No. 19).
Be sure to set pump and suction tube assembled so that the suction tube is at the
desired depth in the drum and is not blocked.