The receiver can be mounted directly on the wall or on a flush-mounted box. First remove the front side, at the bottom there are two recesses which can
be pressed with a screwdriver. The receiver is IP20 rated and should only be installed in dry, non-wet and dusty environments. If the receiver is to be
mounted in a humid and dusty environment, the board can be mounted in a protected junction box.
The receiver is equipped with two terminal blocks of 2 and 3 terminals.
Note: depending on receiver version (4, 10 or 16A)
Variant 2: RFS-plug receiver
The RFS plug connector receiver communicates with the RF-OPTIMA Eazy thermostat. Up to
8 receivers can be connected to one of the thermostats.
Features
Plug receiver, easy to install.
✓
3 Led lamps indicate operating status
✓
One button allows easy pairing with the thermostat
✓
Built-in memory chip
✓
Technical data
Input / Output Voltage:230V
Maximum switching capacity: 3600W/16A
Backup: EEPROM
Frequency: 868Mhz
Dimensions: 70 mm x 41.5 mm x 140mm.
Colour: white
IP protection class: 20
Connection with the thermostat
The RF-OPTIMA Eazy thermostat and receiver are equipped with a binary code for setting the channel. The receiver is equipped with a
button for "pairing" with the thermostat. If the thermostat and receiver are not already paired, proceed as follows:
- Press button (A) Pairing button on the receiver, the LED flashes (B).
- Switch off the thermostat by pressing the round knob.
- Press the thermostat knob again for 3 seconds, the lower right display will show 0.0°C. Press the rotary knob once again, a code is
displayed in the middle of the display (e.g.: 39 9c).
- Turn the knob counterclockwise, the LED on the receiver goes out. Thermostat and receiver are now "coupled".
- Press the round knob on the thermostat to switch it on again.
A: Set button for pairing with thermostat
B: Indicator LED for pairing status
C: Display LED operating mode
LED permanently green = socket outlet enabled
LED off = socket not enabled
D: Receiver Power LED
Römer Systems GmbH, Raiffeisenstr.2, D 57462 Olpe, Germany, tel.: +49 (0)2761 827151, fax.: +49 (0)2761 2528,
E-Mail: info@roemer-energiesparheizung.de
Mounting and connecting the receiver
COM: Common contact
NO: Normally open contact
NC: Normally closed contact
L + N: connection
Power supply 230Vac.
connections
TBV CV installation
D
C
B
A
URL: www.roemer-energiesparheizung.de
TBV electrical heating