hex
sub Name
0x5F
Measurement Data
Collection
1
Position value
2
Signal quality
3
BD1 status
4
BD2 status
5
BD3 status
Standard operation control
0x70
Output Configuration
1
Output Type Q1
2
Output Type Q2
3
Output Type Q3
4
Analog Output Type UI
5
Current Low Value
6
Current High Value
7
Voltage Low Value
8
Voltage High Value
0x74
Event Configuration
0x7F
Locator Indication
Control
User information
0xC0
UT1 - User Tag 1
0xC1
UT2 - User Tag 2
Special function
0xE2
Operating
Temperature
Data
Type
type
Value
R
record
R
uint16 0 ... 448
R
uint8
0x00 - insufficient / no position
acquisition possible
0x01 - acceptable
0x02 - good
0x03 - excellent
R
uint8
0: inactive
1: active
R
uint8
o: inactive
1: active
R
uint8
0: inactive
1: active
R/W record
R/W
uint8
0x00 - push-pull
0x01 - low-side
0x02 - high-side
R/W
uint8
0x00 - push-pull
0x01 - low-side
0x02 - high-side
0x03 - hi-Z
R/W
uint8
0x02 - high-side
0x03 - hi-Z
R/W
uint8
0x00 - reserved
0x01 - I: 0...20mA
0x02 - I: 4...20mA
0x03 - U: 0...10V
0x04 - U: 1...5V
R/W
uint8
0...200
R/W
uint8
0...200
R/W
uint8
0...100
R/W
uint8
0...100
R/W
uint8
0b0000 0000 - application events
disabled
0bXXXX XXX1 - no target event
enabled
R/W
uint8
0x00 - normal indication
0x01 - locator indication
R/W uint32 0x00000000 ... 0xFFFFFFFF
R/W uint16 0x0000 ... 0xFFFF
R
uint8
Default Unit
1/32mm
0x00
0x00
0x00
0x03
0
0.1mA
200
0.1mA
0
0.1V
100
0.1V
0x00
0x00
0
0
°C
37