Caractéristiques techniques
Tension de service......................: 230 VCA.
Fréquence du secteur.................: 50 Hz
Tensions de sortie ......................: de 6 VCC min. à 24 VCC max.,
selon 6 niveaux
Courant de sortie........................: 1,0 A max. pour le modèle
SNG 1000/24
1,5 A max. pour le modèle
SNG 1500/24
Puissance utile ...........................: 24 VA max. ou 39 VA
Température de service..............: de 0°C à +40°C max.,
lorsque l'humidité relative de l'air est inférieu-
re à <80%, sans condensation
Dimensions (L x l x h) ................: 105 x 60 x 38 mm
(sans câble de raccordement)
Longueur du terminal de sortie...: 1,9 m env. avec raccord à 2 pôles
22
- moisture or excessive (air) humidity,
- dust and combustible gases, vapours or solvents,
- severe vibrations.
Any use deviating from that described above results in product damage; it
moreover involves danger, e.g. short-circuits, fire, electric shocks etc. The entire
product must not be changed or modified! It is essential to adhere to the safety
provisions!
Adjustment controls
1. Control LED
2. Change-over switch for the different output voltages
3. Connection cable for the extra-low-voltage plug

Safety provisions

Any damage caused by non-compliance with the operating instructions rule out
your warranty claim! We shall not be held liable for consequential damage resul-
ting from such non-compliance.
We shall not be held liable for material or personal damage resulting from impro-
per handling or non-compliance with the safety provisions. In such cases, any
warranty claims are ruled out.
• The plug-in power supply unit has been delivered from our factory in perfectly
safe technical condition. To maintain this state and to ensure safe operation,
the user must adhere to the safety provisions and warnings contained in these
operating instructions. The unit has been designed for safety class II.
• It is essential that the insulation is neither damaged nor destroyed.
• The power pack must not be used directly as charging unit. Moreover, the po-
wer pack is not protected against overload and/or short-circuit at the output.