ENGLISH
Lighting
Turn on the gas supply tap.
1)
Press and turn the knob (A) anti-clockwise
2)
(pos.1) to turn on the pilot light.
Hold the knob down for approximately 15
3)
sec. to start up the thermocouple.
Turn the knob (A) anti-clockwise (pos.2) to
4)
light the burner.
Press and turn the knob gradually anti-clock-
5)
wise to adjust the power of the fl ame down
to the minimum setting.
Turning off
Turn the knob (A) clockwise (pos. 1) to turn
1)
the burner off . The pilot light will remain on
to allow the burner to be re-lit.
Press and turn the knob clockwise (pos. 3) to
2)
turn off the pilot light.
Turn off the gas supply tap to ensure safety.
3)
20
SWITCHING THE TOP BURNER ON AND OFF
USE AND OPERATION
A
A
3
3320050_ut_GB_rev.2
1
2