Herunterladen Inhalt Inhalt Diese Seite drucken
Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 11
L2423
Rev. A
Index:
English: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-5
Français: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-10
Deutsch: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11-15
Italiano: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16-20
Español: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21-25
Nederlands: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26-30
Portuguese: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .31-35
: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36-35
1.0 IMPORTANT RECEIVING INSTRUCTIONS
Visually inspect all components for shipping damage. Shipping
damage is not covered by warranty. If shipping damage is found,
notify carrier at once. The carrier is responsible for all repair and
replacement costs resulting from damage in shipment.
SAFETY FIRST
2.0 SAFETY ISSUES
Read all instructions, warnings and cautions
carefully. Follow all safety precautions to avoid
personal injury or property damage during system
operation. Enerpac cannot be responsible for damage or injury
resulting from unsafe product use, lack of maintenance or incorrect
product and/or system operation. Contact Enerpac when in doubt
as to the safety precautions and operations. If you have never been
trained on high-pressure hydraulic safety, consult your distribution
or service center for a free Enerpac Hydraulic safety course.
Failure to comply with the following cautions and warnings could
cause equipment damage and personal injury.
A CAUTION is used to indicate correct operating or maintenance
procedures and practices to prevent damage to, or destruction of
equipment or other property.
A WARNING indicates a potential danger that requires correct
procedures or practices to avoid personal injury.
A DANGER is only used when your action or lack of action may
cause serious injury or even death.
WARNING: Wear proper personal protective gear
when operating hydraulic equipment.
WARNING: Stay clear of loads supported by
hydraulics. A cylinder, when used as a load lifting
device, should never be used as a load holding device.
After the load has been raised or lowered, it must always be
blocked mechanically.
WARNING: USE ONLY RIGID PIECES TO HOLD LOADS.
Carefully select steel or wood blocks that are capable
of supporting the load. Never use a hydraulic cylinder
as a shim or spacer in any lifting or pressing application.
®
11/01
Instruction Sheet
PTA-3408 Air / Hydraulic Torque Wrench Pump
PTA-3408 pumps are designed for use with single- and
double-acting torque wrenches and feature remote pendant
operation. PTA-3408 pumps are equipped with air filter
lubricators, glycerin-filled pressure gauges, and adjustable
pressure relief valves.
SPECIFICATIONS
Air Requirements for Max. Pressure
Hydraulic Flow at 0 psi [0 bar]
at 10,000 psi [700 bar] 30 in
Adjustable Relief Valve Adjustment
Reservoir Capacity
Reservoir Capacity (usable)
Noise
DANGER: To avoid personal injury keep hands
and feet away from cylinder and workpiece
during operation.
WARNING: Do not exceed equipment ratings. Never
attempt to lift a load weighing more than the capacity
of the cylinder. Overloading causes equipment failure
and possible personal injury. The cylinders are designed for a
max. pressure of 800 bar [11,600 psi]. Do not connect a jack or
cylinder to a pump with a higher pressure rating.
Never set the relief valve to a higher pressure than the
maximum rated pressure of the pump. Higher settings
may result in equipment damage and/or personal injury.
Figure 1
100 psi [7.0 bar] at 65 max SCFM
3
600 in
/min [9.83
/min]
L
3
/min [0.49
/min]
L
11,600 psi [800 bar]
2.5 gal. [9,4 L]
1.9 gal. [7,2 L]
80-90 dBA at 100 psi [7.0 bar]
Inhaltsverzeichnis
loading

Inhaltszusammenfassung für Enerpac PTA-3408

  • Seite 11: Wichtige Verfahrenshinweise Für Den Empfang

    Abbildung 1 des Systems verursacht werden. Bei evtl. Fragen in bezug auf Sicherheitsvorkehrungen und Betriebsabläufe wenden Sie sich bitte Die Pumpen PTA-3408 sind für einfach und doppelt wirkende an ENERPAC. Wenn Sie an keinerlei Sicherheitsschulungen im hydraulische Drehmomentschlüssel vorgesehen und zur Zusammenhang mit Hochdruckhydraulikanlagen teilgenommen Fernsteuerung geeignet.
  • Seite 12: Druckluftanschluss

    Überwachung des Betriebsdrucks sind Manometer im System Kundendienstzentrale der jeweiligen Region wenden. Zur zu installieren. Dies ist das Fenster zu den Abläufen im System. Aufrechterhaltung der Garantie nur ENERPAC-Öl verwenden. VORSICHT: Beschädigungen am Hydraulikschlauch WARNUNG: Abgenutzte oder beschädigte Teile vermeiden. Beim Verlegen der Hydraulikschläuche unverzüglich durch ENERPAC-Originalteile ersetzen.
  • Seite 13: Auffüllen Des Druckluftölers

    Drehmomentschlüssel anschließen. Die Sicherungsringe der Kontrolle Kupplung drehen. Die Enerpac-Schläuche und Kupplungen Ölstands für den sind bei Verwendung der Enerpac-Pumpe und des Druckluftöler ist für die hydraulischen Drehmomentschlüssels so geformt, dass der Lebensdauer der Pumpe Anschluss zum Ausfahren der Pumpe nur an den Anschluss entscheidend.
  • Seite 14: Entlüftung

    Abbildung 9). Setzen Sie die neue Wechselskala auf die Frontplatte (beachten Sie, dass Sie die richtige Wechselskala für den Drehmomentschlüssel von Enerpac verwenden) und richten Sie die Wechselskala auf die Nasen an der Rückseite der Abbildung 11 Frontplatte aus (siehe Abbildung 10).
  • Seite 15: Reinigung Des Luftfilters Und Druckluftölers

    Fassungsvermögen Folgende Informationen sollen als Hilfe bei der Erkennung von Hydraulikbehälter beträgt 9,4 Liter (2,5 US-Gall.). Problemen dienen. Zur Durchführung von Reparaturen ist die Fachwerkstatt von Enerpac zu benachrichtigen. Den Deckel des Luftfilters wieder aufsetzen. VERBRAUCHTES ÖL KORREKT ENTSORGEN. FEHLERSUCHDIAGRAMM Problem Mögliche Ursache...
  • Seite 36 ® L2423 11/01...
  • Seite 38 ENERPAC 11,600 PSI (800 BAR) ENERPAC 11,600 PSI (800 BAR)

Inhaltsverzeichnis