Herunterladen Inhalt Inhalt Diese Seite drucken

Technical Data; Troubleshooting - EINHELL LE-HGG 110 Bedienungsanleitung

Heissluftgenerator
Vorschau ausblenden Andere Handbücher für LE-HGG 110:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
Anleitung HGG 110-300_SPK7

8. Technical Data

LE-HGG 110
HGG 110 Niro
Nominal heat load Qu:
max. (Hi) 11,2 kW
Air throughput:
500 m
3
/h
Connection:
G 30: 815 g/h
Equipment category:
I3B/P
Type of gas:
commercially
available propane
(DIN 51622)
commercially
available butane
(DIN 51622)
Operating pressure P:
300 mbar
Mains power supply:
230 V ~ 50 Hz 38 W
9. Trouble Shooting
Problem
Cause
Motor doesn't start
No electricity
Piezo doesn't ignite
Electrode incorrectly adjusted
No gas at burner
- Gas valve is closed
- Gas cylinder is empty
- Gas hose or connection leaks
Burner ignites, flame is
- The thermoelement was not
extinguished as soon as the gas
-
warm enough
valve is released
- The safety thermostat
-
-
switches off
Burner goes out while in use
- Gas flow too high
- Air input too low
Important!
Have repairs carried out only by specialist workshops or ISC.
16.01.2006
12:47 Uhr
HGG 171 Niro
HGG 300 Niro
LE-HGG 110-CH
max. (Hi) 17 kW
max. (Hi) 30 kW
max. (Hi) 9,5 kW
500 m
3
/h
500 m
3
/h
500 m
G 30: 1430g/h
G 31: 2150 g/h
G 31: 815 g/h
I3B/P
I3P
I3P
commercially available
commercially available
commercially available
propane (DIN 51622)
propane (DIN 51622)
propane (DIN 51622)
commercially available
butane (DIN 51622)
300 mbar
1500 mbar
300 mbar
230 V ~ 50 Hz 38 W
230 V ~ 50 Hz 38 W
230 V ~ 50 Hz 38 W
Remedy
- Check electrical outlet
- Check mains cable
Check electrode and precisely
set according to diagram
- Open valve
- New gas cylinder
- Locate point of leak with soap
-
foam and repair
- Repeat ignition procedure
-
while pressing in the gas
-
valve knob
- Allow the heater to cool for a
-
few minutes and reignite
- Have the pressure regulator
-
inspected and replace if
-
necessary
- Check the suction grid and
-
clean
- Inspect ventilator
Seite 11
GB
3
/h
11

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis