  • DEUTSCH, seite 84
• 10 short beeps and a red LCD backlight alert the patient
that he/she may have a temperature above 37.5 °C.
Ear measurement
Straighten the ear canal by pulling the ear up and back
to give a clear view of the eardrum.
• For children under 1 year; pull the ear straight back.
• For children of 1 year to adult; pull the ear up and back.
Also refer to the short instructions at the front.
While gently pulling the ear, insert the probe snugly into
the ear canal (max. 1 sec.) and immediately press the
START button 2. Release the button and wait for the
beep sound that confirms the end of measurement.
Remove the thermometer from the ear canal. The display
shows the measured temperature 9.
NOTE:
• To ensure accurate readings, wait at least 30 sec.
after 3-5 continuous measurements.
• Accumulation of ear wax on the probe can result in less
accurate temperature readings or cross infection between
users. Therefore, it is essential that the probe is clean
before each measurement. For cleaning, follow the
instructions in the «Cleaning and Disinfecting» section.
6
• After cleaning the measuring sensor 1 with
alcohol, wait 5 minutes before taking the next
measurement, in order to allow the thermometer to
reach its operating reference temperature.
• For an infant, it is best to have the child lying flat with
his/her head sideways so the ear is facing upwards. For
an older child or adult, it is best to stand behind and
slightly to the side of the patient.
• Always take the temperature in the same ear, since the
temperature readings may be different from ear to ear.
• Wait for a few minutes to take the ear temperature after
sleeping.
• In the following situations it is recommended that three
temperatures in the same ear be taken and the highest
one taken as the reading:
1. New born infants in the first 100 days.
2. Children under three years of age with a compromised
immune system and for whom the presence or
absence of fever is critical.
3. When first-time users are learning how to use the
thermometer until they have familiarized themselves
with the instrument and obtain consistent readings.
4. If the measurement is surprisingly low.

7. Changing between Celsius and Fahrenheit

This thermometer can display temperature measurements in
either Fahrenheit or Celsius. To switch the display between
°C and °F, simply turn OFF the unit, press and hold the
START button 2 for 5 seconds; after 5 seconds, the current
measurement scale («°C» or «°F» icon) will be flashing on the
display AL. Change the measurement scale between °C and
°F by pressing the START button 2. When the measurement
scale has been chosen, wait for 5 seconds and the unit will
automatically enter the «ready for measuring» mode.

8. How to recall 12 readings in Memory Mode

This thermometer can recall the last 12 readings.
• Recall mode AM: Press the START button 2 to enter
Recall mode when power is off. The memory icon «M»
will flash.
• Reading 1 - the last reading AN: Press and release the
START button 2 to recall the last reading. Display 1
alone with memory icon.
• Reading 12 - readings in succession: Press and
release the START button 2 consecutively to recall the
last 12 readings in succession.