Fault
Pump runs but does not
transport
Pump does not run or sud-
denly comes to a standstill
during operations
Pump stops, LED "Error on
suction side" is illuminated.
Troubleshooting
Cause
Air in the pump
Suction pipe blocked
Pre-filter is dirty
Suction hose or connection
adapter not screwed in correct-
ly or completely.
Power supply interrupted
Pre-filter is dirty
The appliance is in the auto-
matic mode.
Pressure in the system >
1.3 bar.
Failure on the suction side,
pressure cannot build up
Flow rate very low -> the dry
run protection has switched off
the pump.
Fault delivery side (leakage or
closed tap) during suction.
Pump does not end the suction
mode.
Remedy
see Chapter "Preparation" Fig. A to D and Chapter
"Operation"
Switch off the pump, pull the mains plug and clean the
intake area.
Switch off the pump, pull the mains plug, allow the
pump to cool down, clean intake area, prevent dry run-
ning.
Remove the pre-filter and the check valve and clean it
under running water, flush dirt residues from the bot-
tom of the filler neck through the filler hole if necessary.
Restart by switching the pump back on.
Check whether all seals have been installed and are
seated correctly prior to assembly.
Manually tighten the suction hose and the connection
adapter.
Check fuses and electrical connections
Remove the pre-filter and the check valve and clean it
under running water, flush dirt residues from the bot-
tom of the filler neck through the filler hole if necessary.
The pump automatically switches back on as soon as
the pressure in the system falls below 1.3 bar.
In automatic mode the device does not start up even
after switching it off and back on if there is an internal
pressure of more than 1.3 bar, thus, when a water col-
umn of more than 13 metres affects the pump.
Switch off the pump and pull the power plug.
Remove the pre-filter and the check valve and clean it
under running water, flush dirt residues from the bot-
tom of the filler neck through the filler hole if necessary.
Restart by switching the pump back on.
Check connections on the suction side for leakage.
Restart by switching the pump back on.
Check if there is sufficient water in the suction contain-
er (e.g. cistern).
Check if there is sufficient water in the suction contain-
er (e.g. cistern).
The flow is insufficient. Open tap more.
Open tap.
Check system for leakage. If the leakage cannot be
eliminated, install pressure equalization container.
(see special accessories)