Einstelleung der konfigurationsschalter für lesekopf

Werbung

Einstellung der Konfigurationsschalter für Lesek pf WCS2 . ..
Setting of configuration switches for reading head WCS2 . ..
S 2
S 1
Bild 1 / Fig. 1
Bild 2 / Fig. 2
Rechte Platine / Right circuit board
S 2
Bild 3 / Fig. 3
Horizontale Platine / Horizontal circuit board
RS485-Abschlu widersta
RS485 Terminating resistor
1
EIN / enabled
ON ON
AUS / disabled
OF OF
Zumutbare Änderungen aufgrund technischer Verbesserungen vorbehalten.
Subject to reasonable modifications due to technical advances.
Pepperl+Fuchs GmbH • 68301 Mannheim • Telefon +49 621 776-1111 • Telefax +49 0621 776-271111 • Internet http://www.pepperl-fuchs.com
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
Konfigurationschalter im Lesekopf
Im Lesekopf kann die Hard- und Softwarekonfiguration
des Lesekopfes verändert werden. Die Änderung des
Lesekopftyps, insoweit möglich, erfolgt mit zwei DIP-
Schaltern, die sich im Lesekopf befinden: S1 und S2.
(Siehe Bild 1). S1 ist ein DIP-Schalter mit 4 Schalters-
tellungen und S2 ein Schalter mit 2 Schalterstellungen.
Um die Schalter verstellen zu können muss der Ge-
häusedeckel abgenommen werden. Dazu werden die
4 Schrauben an der Gehäuseunterseite gelöst.
Änderung der Lesekopfadresse bei Lesekopf
mit RS485-Schnittstelle
Lesekopf-Typ
1
WCS2.-LSxxx-0
OFF OFF
WCS2.-LSxxx-1
ON OFF
WCS2.-LSxxx-2
OFF ON
WCS2.-LSxxx-3
ON
Änderung des Abschlusswiderstandes bei
Lesekopf mit RS485-Schnittstelle
Lesekopf mit RS485-Abschlusswiderstand (-LS2..):
beide Schalter von S2 auf Stellung ON
Lesekopf ohne RS485-Abschlusswiderstand (-LS1..):
S 1
beide Schalter von S2 auf Stellung OFF
Änderung der Baudrate bei Lesekopf mit RS485-
Schnittstelle
Basistypen LS211/LS221:
Lesekopf-Typ
1
WCS2.-LSn11
X
WCS2.-LSn21
X
Mit S1, Schalter 4 =ON wird die Ausgabe der Ver-
schmutzungswarnung auf das Diagnosebit (DB) unter-
drückt.
Basistypen LS231/LS261:
Lesekopf-Typ
1
WCS2.-LSn61
X
WCS2.-LSn31
X
Basistypen LS246/LS256:
Lesekopf-Typ
1
WCS2.-LSn46
X
WCS2.-LSn47
X
WCS2.-LSn56
X
WCS2.-LSn57
X
n=1,2
Wichtig!
Wenn die Adresse, die Baudrate geändert
und/oder der RS485-Abschlusswiderstand
ein-/ausgeschaltet wurde, bitte unbedingt die
Lesekopfbezeichnung auf dem Typenschild
entsprechend obiger Tabelle abändern.
S2
Beispiele:
- Adresse von 0 auf 1 geändert:
2
Bezeichnung WCS.-LS211(-0)
- RS485-Abschlusswiderstand ausgeschaltet:
Bezeichnung WCS.-LS211 in WCS.-LS111 ändern
- Baudrate von 187,5 kBaud auf 62,5 kBaud geändert:
Bezeichnung WCS.- LS211 in WCS.- LS221 ändern
*) Wenn keine Adresse explizit in der Lesekopfbezeichnung
angegeben ist, dann ist standardmäßig die Adresse 0 eingestellt.
Configuration switches inside the WCS
reading head
The configuration of the reading head can be changed
by two DIL switches which are located inside the read-
ing head – S1 and S2. (see Fig 1).To change the
switches the housing of the reading head must be
opened. Srew up the four screws for the housing.
Changing of the reading head address (reading
head with RS485 interface only)
S1
Adresse
2
3
4
X
X
0
X
X
1
X
X
2
ON
X
X
3
Changing of the RS485 terminating resistor
(reading head with RS485 interface only)
Reading head with terminating resisitor (-LS2..):
switch S2: booth switches are ON
Reading head without terminating resisitor (-LS1..):
switch S2: booth switches are OFF
Changing of the baud rate at reading head with RS485
interface
Base types LS211/LS221:
S1
Baudrate
2
3
4
X
OFF
X
187,5 kBaud
X
ON
X
62,5 kBaud
Setting S1, switch 4 = ON suppresses the output of
the contamination warning on the diagnostic bit
(DB).
Base types LS231/LS261:
S1
Baudrate
2
3
4
X
OFF
X
38,4 kBaud
X
ON
X
31,25 kBaud
Base types LS246/LS256:
S1
Baudrate
2
3
4
19,2 kBaud
X
OFF
OFF
even parity
19,2 kBaud
X
OFF
ON
no parity
9,6 kBaud
X
ON
OFF
even parity
9,6 kBaud
X
ON
ON
no parity
n=1,2
Important
If the configuration of the reading head was
changed , please change the type code on the
reading head label, too.
Examples:
Reading head address was changed from 0 to 1:
*)
in WCS.-211-1 ändern
·Deactivation of RS485 terminating resistor:
·Baud rate was changed, from 187.5 kBaud to 62.5 kBaud:
*) If the address is not explicit mentioned at the reading head
mit RS485-Schnittstelle
with RS485 interface
S1
Reading head
1
2
3
WCS3.-LSxxx-0
OFF OFF
X
WCS3.-LSxxx-1
ON
OFF
X
WCS3.-LSxxx-2
OFF ON
X
WCS3.-LSxxx-3
ON
ON
X
S1
Reading head
type
1
2
3
WCS2.-LSn11
X
X
OFF
WCS2.-LSn21
X
X
ON
S1
Lesekopf-Typ
1
2
3
WCS2.-LSn61
X
X
OFF
WCS2.-LSn31
X
X
ON
S1
Reading head type
1
2
3
WCS2.-LSn46
X
X
OFF
WCS2.-LSn47
X
X
OFF
WCS2.-LSn56
X
X
ON
WCS2.-LSn57
X
X
ON
Modify designation from WCS.-LS211(-0)
Modify designation from WCS.-LS211-0 to WCS.-LS111-0
Modify designation from WCS.-LS211-0 -> WCS.-LS221-0
designation, then
it is default Adr.0
Copyright Pepperl+Fuchs, Printed in Germany
Address
4
X
0
X
1
X
2
X
3
Baud rate
4
X
187,5 kBaud
X
62,5 kBaud
Baud rate
4
X
38,4 kBaud
X
31,25 kBaud
Baud rate
4
19,2 kBaud
OFF
even parity
19,2 kBaud
ON
no parity
9,6 kBaud
OFF
even parity
9,6 kBaud
ON
no parity
*)
to WCS.-211-1
1

Werbung

loading

Inhaltszusammenfassung für Pepperl+Fuchs WCS2 LS 0 Serie

  • Seite 1 Copyright Pepperl+Fuchs, Printed in Germany Pepperl+Fuchs GmbH • 68301 Mannheim • Telefon +49 621 776-1111 • Telefax +49 0621 776-271111 • Internet http://www.pepperl-fuchs.com Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com...
  • Seite 2 Copyright Pepperl+Fuchs, Printed in Germany Pepperl+Fuchs GmbH • 68301 Mannheim • Telefon +49 621 776-1111 • Telefax +49 0621 776-271111 • Internet http://www.pepperl-fuchs.com Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com...

Diese Anleitung auch für:

Wcs2 ls 1 serieWcs2 ls 2 serieWcs2 ls 3 serieWcs3 ls 0 serieWcs3 ls 1 serieWcs3 ls 2 serie ... Alle anzeigen